216653

PEEK Versus Metallic Framework For Extracoronal Attachment Mandibular Bilateral Distally Extended Removable Dental Prosthesis (RDP) Evaluation of Abutments Bone Height Changes an

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

Purpose: to evaluate bone height changes around distal abutments (canines) with two different framework materials for extracoronal attachment mandibular bilateral distally extended removable dental prosthesis (RDP) and compare patient satisfaction .
Materials and methods:

Twenty-eight mandibular Kennedy class I partially edentulous patients with remaining 6 anterior teeth were selected. For all patients splinting of remaining anterior abutments by porcelain fused to metal crowns, the RDP frameworks were designed by CAD and printed into 3-D resin pattern. The patients were randomly divided into two groups. Patients in group I received extracoronal attachment RDP framework fabricated from milled BioHPP PEEK while patients in group II received extracoronal attachment RDP framework fabricated from Cobalt -Chromium (Co-Cr) material. Digital radiography was used for vertical bone loss (VBL) assessment around canines at insertion, 6 and 12 months. Patient satisfaction was measured after 6 months using visual analog scale (VAS). Statistical analysis was done by t-test and Mann-Whitney.
Results: VBL significantly increased from T6 to T12 for both groups where (p=0.038 and 0.021) for PEEK and Co-Cr framework respectively. there was a significant difference in VBL between two groups at T12 only (p=0.012) where Co-Cr framework recorded significant higher VBL at T12 than PEEK. As for patients satisfaction, patients who received PEEK RDP frameworks were more satisfied as regards esthetic and comfort than patients who received Co-Cr RDP frameworks
Conclusion: Extracoronal attachment RDPs with PEEK frameworks showed less VBL than those with Co-Cr frameworks. Patients with PEEK frameworks were more satisfied than patients with Co-Cr frameworks

DOI

10.21608/edj.2021.93903.1778

Keywords

Framework materials, patient satisfaction, PEEK, Bone changes

Authors

First Name

nourhan

Last Name

ragheb

MiddleName

-

Affiliation

Lecturer, Department of Prosthodontics, Faculty of Oral & Dental Medicine, Kafrelsheikh University, Kafr El-sheikh, Egypt

Email

norhan_ragheb@den.kfs.edu.eg

City

-

Orcid

-

First Name

Mohamed

Last Name

Elgamal

MiddleName

-

Affiliation

Lecturer, Prosthodontist, Department of removable Prosthodontics, Faculty of Dentistry, Mansoura University, Eldakahlia , Egypt.

Email

drelgamal@mans.edu.eg

City

-

Orcid

-

Volume

68

Article Issue

1

Related Issue

30583

Issue Date

2022-01-01

Receive Date

2021-09-01

Publish Date

2022-01-01

Page Start

631

Page End

645

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_216653.html

Detail API

https://edj.journals.ekb.eg/service?article_code=216653

Order

6

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

PEEK Versus Metallic Framework For Extracoronal Attachment Mandibular Bilateral Distally Extended Removable Dental Prosthesis (RDP) Evaluation of Abutments Bone Height Changes an

Details

Type

Article

Created At

22 Jan 2023