Beta
201884

RADIOGRAPHIC EVALUATION OF THE EFFECT OF IMPLANT SUPPORTED AND IMPLANT RETAINED DISTAL EXTENSION REMOVABLE PARTIAL DENTURES ON THE SUPPORTING STRUCTURES

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Objective: To evaluate and compare the effect of implant supported versus implant retained removable partial denture restoring Kennedy's class I cases on the supporting structures by measuring marginal bone loss and bone density around implant.
Subjects and Methods: Twelve patients were selected from the outpatient clinic, Prosthodontics Department, Faculty of Dentistry, Minia University. Both groups were classified into two equal groups; according to the implant superstructures either dome shaped abutment -and-ball and socket attachment. Each Patient of both groups had two implants in second molar position and received removable partial denture of the same design. Patients were followed up for one year radiographicaly regarding marginal bone loss and bone density around each implant. Group I: Six patients received RPD supported by dome shaped short abutments. Group II six patients received RPD retained by ball and socket attachments.
Results: Results revealed that there was Significant increase in marginal bone loss in group II implant retained with ball abutment than group I implant supported with dome shaped abutment and Significant increase in bone density in group I (implant supported) than group II (implant retained)
Conclusion: The use of dome shaped abutment produce less marginal bone loss and increase of bone density than the use of ball abutment.

DOI

10.21608/edj.2021.86774.1717

Keywords

implant supported, implant retained, removable partial over denture

Authors

First Name

Ragia

Last Name

Kotb

MiddleName

Saad

Affiliation

Clinical instructor at Removable Prosthodontics department Faculty of Dentistry Alexandria University.

Email

ragiakotb@gmail.com

City

Alexandria

Orcid

-

First Name

Ahmed

Last Name

Ahmed Hassan

MiddleName

-

Affiliation

Associate Professor of Prosthodontics, Faculty of Dentistry, Minia University, Egypt.

Email

drahmedgamal2002@yahoo.com

City

Minia

Orcid

-

First Name

Emad

Last Name

Agamy

MiddleName

-

Affiliation

Professor of Prosthodontics, and Vice Dean for Education and Student Affairs, Faculty of Dentistry, Minia University, Egypt

Email

emad_agamy@yahoo.com

City

Minia

Orcid

0000-0003-4335-8005

First Name

Gihan

Last Name

Mohammed

MiddleName

-

Affiliation

Professor of Prosthodontics and vice President, Kantara University; Egypt

Email

gogofekry_2010@yahoo.com

City

Minia

Orcid

-

Volume

67

Article Issue

4

Related Issue

28415

Issue Date

2021-10-01

Receive Date

2021-07-17

Publish Date

2021-10-01

Page Start

3,509

Page End

3,517

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_201884.html

Detail API

https://edj.journals.ekb.eg/service?article_code=201884

Order

22

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

RADIOGRAPHIC EVALUATION OF THE EFFECT OF IMPLANT SUPPORTED AND IMPLANT RETAINED DISTAL EXTENSION REMOVABLE PARTIAL DENTURES ON THE SUPPORTING STRUCTURES

Details

Type

Article

Created At

22 Jan 2023