Beta
201457

Radiographic Assessment of Digital Tray Technique versus Conventional Technique on the Accuracy of Mandibular Screw Retained Implant Overdentures

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Abstract

Purpose: This study purposed to be introduced to evaluate the effect of the digital tray technique used on the accuracy of mandibular screw-retained implant overdentures compared with complete denture incorporated with barium sulfate as a radiographic stent. Materials and Methods: Forty-eight patients were examined for implant placement. Each implant site was planned virtually using two different techniques: denture duplication technique with barium sulfate incorporation and digital tray technique. Implantation placement had been performed in both groups using the same three-dimensional manufactured radiographic stent. Post insertion CBCT was introduced with simulated scheduling images. Angular deviation, global deviation, lateral deviation, and depth of implant placement were collected for planned and placed implants of both groups. Results: Using an independent t-test for significance assessment of global, lateral, and angular deviation between both groups, it was revealed that there was a significant difference between both groups and an insignificant difference for implant depth. Conclusion: Within limitations regarding radiographic accuracy depending on the radiographic technique; it showed less deviation of digital tray group than conventional denture duplication technique with barium sulfate incorporation.

DOI

10.21608/edj.2021.76565.1638

Keywords

Keywords: Digital, Implant, accuracy, Denture, radiograph

Authors

First Name

Aya

Last Name

Fawzy

MiddleName

-

Affiliation

Department of Removable Prosthodontics, Faculty of Oral and Dental Medicine, Future University in Egypt, Egypt

Email

ayamoh.fawzy17@gmail.com

City

Cairo

Orcid

0000-0001-9226-940X

First Name

Shady

Last Name

El Naggar

MiddleName

-

Affiliation

Department of Removable Prosthodontics, Faculty of Oral and Dental Medicine, Badr University in Cairo, Egypt.

Email

dr_shady_1985@hotmail.com

City

-

Orcid

0000-0002-7809-7354

Volume

67

Article Issue

4

Related Issue

28415

Issue Date

2021-10-01

Receive Date

2021-05-19

Publish Date

2021-10-01

Page Start

3,291

Page End

3,304

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_201457.html

Detail API

https://edj.journals.ekb.eg/service?article_code=201457

Order

1

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Radiographic Assessment of Digital Tray Technique versus Conventional Technique on the Accuracy of Mandibular Screw Retained Implant Overdentures

Details

Type

Article

Created At

22 Jan 2023