Beta
185166

Effect of span length on the trueness of an intraoral scanner. (An in-vitro study)

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Abstract
Statement of the problem:
Digital scanning has been widely used nowadays, however its accuracy in relation to the bridge span length needs further investigations.
Objective:
The aim of this study was to determine the effect of span length on the trueness of an intra-oral scanner.
Materials and methods:
On a typodont (Nissin Dental Model, Japan) preparations for two bridge span lengths were made. One resembling missing upper second premolar representing short straight span length (SS) while the second resembling missing upper first and second premolars representing long curved span (LS). Then typodont was scanned by a laboratory scanner (InEos X5 scanner) (Sirona Dental System, Bensheim, Germany) to act as a reference model scan to compare measurements for trueness. Then for each group five scans were taken for the typodont by Medit intraoral scanner (iScan version 1.2.0.1; Medit, Seoul, Korea) to be compared with the reference scan. Then data set from the scans were transferred to STL format and then exported to exocad (exocad version 2.3 Matera exocad GmbH,Darmstadt, Germany) software to get the measurements to determine the trueness.
Results:
Results of this study showed that in the comparison between short and long span bridges, the long span bridge scans showed statistically significant higher root mean square (RMS) mean value (0.23±0.10 mm), lower trueness than short span bridge scans (0.06±0.04 mm).
Conclusions:
Long span fixed bridge had an adverse effect on the scanning accuracy. Trueness of intraoral scanner may be affected by the complexity and length of the scanning area.

DOI

10.21608/edj.2021.78409.1655

Keywords

span length, Trueness, Intraoral scanning

Authors

First Name

Noha

Last Name

Elkhodary

MiddleName

-

Affiliation

Lecturer of Fixed Prosthodontics Department Faculty of Dentistry, Cairo University, Egypt.

Email

noha.elkhodary@dentistry.cu.edu.eg

City

-

Orcid

0000-0003-1511-1654

Volume

67

Article Issue

3

Related Issue

26731

Issue Date

2021-07-01

Receive Date

2021-05-31

Publish Date

2021-07-01

Page Start

2,605

Page End

2,612

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_185166.html

Detail API

https://edj.journals.ekb.eg/service?article_code=185166

Order

37

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect of span length on the trueness of an intraoral scanner. (An in-vitro study)

Details

Type

Article

Created At

22 Jan 2023