Beta
185157

Effect of type of reinforcement on clinical denture base deformation with telescopic attachments of implant retained overdentures. A within-subject clinical study.

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

-

Abstract

Abstract
Aim: The aim of this within-subject study was to evaluate and compare clinical denture base deformation with two types of denture base reinforcement for telescopic implant retained overdentures.
Materials and methods: Six completely edentulous participants received two implants in the canine region of the mandible and the implants were connected to the overdentures with resilient telescopic attachments. Each patient received 2 types of denture reinforcement for the mandibular overdentures; 1) metal reinforced overdentures, 2) PEEK reinforced overdentures. Four strain-gauges were adhered to the lingual polished surface of each denture abutment top (C1 and C3), and 5 mm below abutment top (C2 and C4). Strain registrations were performed during maximum voluntary clenching.
Results: The measured strains and implant positions C1 and C3 were tensile in nature and the measured strains at implant positions C2 and C4 were compressive in nature. The highest microstrain was noted at C3, followed by C1, then C2, and the lowest strain was noted was with C4 for both groups. There was no significant difference in recorded microstrains between C1 and C3 or between C2 and C4. For all strain gauge positions, PEEK reinforced overdentures recorded significantly higher microstrains than metal-reinforced overdentures.
Conclusion: Within the limitation of this short term cross over trial, cobalt-chromium metal reinforcement for mandibular implant assisted overdentures is recommended than PEEK reinforcement as it reduced denture base strains and deformation during maximum voluntary clenching.

DOI

10.21608/edj.2021.73116.1598

Keywords

reinforcement, denture base deformation, telescopic attachments, implant retained overdentures

Authors

First Name

Dina

Last Name

El talawy

MiddleName

-

Affiliation

Associate Professor, Removable Prosthodontic Department College of Oral and Dental Surgery, Misr University for Science and Technology,Giza Egypt.

Email

dinaeltalawy@hotmail.com

City

-

Orcid

-

First Name

May

Last Name

Hassan

MiddleName

-

Affiliation

Lecturer, Removable Prosthodontic Department College of Oral and Dental Surgery, Misr University for Science and Technology, Giza Egypt.

Email

beauty_girl8310@hotmail.com

City

Cairo

Orcid

0000-002-9144-5392

Volume

67

Article Issue

3

Related Issue

26731

Issue Date

2021-07-01

Receive Date

2021-04-19

Publish Date

2021-07-01

Page Start

2,489

Page End

2,498

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_185157.html

Detail API

https://edj.journals.ekb.eg/service?article_code=185157

Order

28

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023