Beta
185143

Peri-implant marginal bone height changes in implant-retained overdentures constructed by CAD/CAM or conventional processing technique- A one-year clinical follow-up.

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Abstract
Objective: To evaluate and compare the peri-implant marginal bone height changes in two implant retained overdentures constructed by either CAD/CAM technology or conventional processing techniques.
Background: The digital denture using CAD/CAM technology has proved high beneficial to the elders and/or the compromised edentulous patient, as it can help decrease the treatment burden on the patient by reducing the clinical procedures, number of visits, treatment time, and incurred costs.
Materials and Methods: Twenty completely edentulous patients participated in this study. The patients were randomly allocated to two equal groups of patients (Group A and group B). Group A patients received complete dentures constructed by conventional heat cured technique. Group B patients received complete dentures constructed by CAD/CAM technology. All the patients received two root form implants bilaterally in the canine regions following delayed loading protocol. Locator attachment was then used to retain the overdenture after 3 months healing period. Marginal bone height was radiographically evaluated at baseline, 6 and 12 months after implant loading.
Results: There was a significant loss in marginal bone height around the supporting implants in each study group. However, no significant differences in marginal bone height were recorded between the study groups over the observation period (P > 0.05).
Conclusion: Peri-implant marginal bone height changes with overdentures fabricated by CAD/CAM technique are not different from those changes with overdentures fabricated by a conventional heat curd technique.

DOI

10.21608/edj.2021.68300.1555

Keywords

CAD/CAM, dental implant, overdenture

Authors

First Name

Nasser

Last Name

Shaheen

MiddleName

Hussein

Affiliation

Department of Removable Prosthodontics, College of Oral and Dental Surgery, Misr University for Science and Technology, Cairo, Egypt.

Email

nasser_shaheen@hotmail.com

City

cairo

Orcid

-

First Name

Mahmoud

Last Name

Aly

MiddleName

Darwish

Affiliation

Prosthodontic Department, Faculty of Dentistry- Suez Canal University

Email

mahmouddent2006@hotmail.com

City

Riyadh

Orcid

0000-0003-3784-9633

Volume

67

Article Issue

3

Related Issue

26731

Issue Date

2021-07-01

Receive Date

2021-03-17

Publish Date

2021-07-01

Page Start

2,357

Page End

2,366

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_185143.html

Detail API

https://edj.journals.ekb.eg/service?article_code=185143

Order

14

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Peri-implant marginal bone height changes in implant-retained overdentures constructed by CAD/CAM or conventional processing technique- A one-year clinical follow-up.

Details

Type

Article

Created At

22 Jan 2023