Beta
185138

Trueness of extra-oral scanner in relation to two span lengths. An in-vitro study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Statement of the problem:
Extraoral scanners have been used widely nowadays however there are certain conditions that could affect their accuracy which will subsequently affect the success of the final restoration.
Objective:
The aim of this study was to determine the accuracy of extraoral scanner in relation to two span lengths.
Materials and methods:
A typodont (Nissin Dental, Kyoto Japan) was used and two bridges with different span lengths were prepared, the first one with missing upper left second premolar (short straight span (GS)) and the other with missing upper left first and second premolars (long curved span (GL)). Indentations were made on each abutment to be taken as a reference for measurements. For both groups reference scan was taken by inEos X5 extra-oral scanner. Then five physical impression was taken for each group using vinylpolysiloxane impression material (Honigum, Germany) and then poured into type IV dental stone. Casts of each group were scanned using DOF extraoral scanner (DOF Company, Korea). Measurements were made from the indentations on the reference scan and the sample scans, compared with each-other and root mean square value (RMS) was obtained to evaluate the trueness.
Results:
Comparison between short and long span bridges revealed that there was no statistically significant difference between trueness values of short and long span bridges. Where RMS mean for the short span was 0.0727 mm and that for the long span was 0.1069 mm.
Conclusions:
Different span lengths do not seem to affect the trueness of the extra-oral scanner tested.

DOI

10.21608/edj.2021.78447.1656

Keywords

Trueness, span lengths, Extraoral scanner

Authors

First Name

Karim

Last Name

Aboubakr

MiddleName

-

Affiliation

Lecturer of Fixed Prosthodontics Department Faculty of Dentistry, Cairo University, Egypt.

Email

karimaboubakr@dentistry.cu.edu.eg

City

-

Orcid

0000-0001-9179-0543

Volume

67

Article Issue

3

Related Issue

26731

Issue Date

2021-07-01

Receive Date

2021-05-31

Publish Date

2021-07-01

Page Start

2,301

Page End

2,308

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_185138.html

Detail API

https://edj.journals.ekb.eg/service?article_code=185138

Order

9

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Trueness of extra-oral scanner in relation to two span lengths. An in-vitro study

Details

Type

Article

Created At

22 Jan 2023