Purpose: The aim of this study is to study the impact of change in kilovoltage (KV) or voxel size on extracted 3D radiographic volume measurement of different sizes of endodontic files and to determine the optimal exposure parameters for volume measurement in CBCT.
Methods: Eight different endodontic k files were radiographically exposed at three different kilovoltages using CBCT and divided into three groups, group 1 (80 KV ), group 2 (60 KV ), and group 3 (50 KV ), then exposed to two different voxel sizes, and divided into two groups, group a (300 μm) and group b (180 μm). The 3D radiographic volume and the actual files volumes were measured using ITK-SNAP software and water displacement method respectively.
Finding: Regarding changes in the kilovoltages, no significant difference ( p ˃0.05 ) was reported between the mean of the 3D radiographic volume of groups 3 and 2 with the mean of actual volume with a mean difference of 1.1 ±7.7 mm3 and 2.6 ±9.6 mm3 respectively. The results for voxel size change, showed no significant difference between the mean of the 3D radiographic volume of group (b) and actual volume group with a mean difference of 1.9 ±7.8 mm3. In the other hand, the difference between the mean of volume measurement at group (a) and actual group became significant with a mean difference of 10.5 ±5.7 mm3 was found.
Conclusion: it concluded that both changes in kilovoltage and voxel size parameters affect significantly the 3D volume measurement and reconstruction.

DOI

10.21608/edj.2021.79717.1669

Keywords

voxel size, 3D Volume, CBCT, ITK-SNAP

Authors

First Name

Mohamed

Last Name

Elboraey

MiddleName

-

Affiliation

Lecturer of Oral Medicine, Periodontology, Oral Diagnosis and Radiology Department, Faculty of Dentistry, Tanta University, Tanta, Egypt.

Email

mohamedomarelboraey@gmail.com

City

tanta

Orcid

0000-0003-1694-712X

Volume

67

Article Issue

3

Related Issue

26236

Issue Date

2021-07-01

Receive Date

2021-06-08

Publish Date

2021-07-01

Page Start

2,205

Page End

2,212

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_182134.html

Detail API

https://edj.journals.ekb.eg/service?article_code=182134

Order

11

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect of Change of Kilovoltage and Voxel Size on 3D Volume Measurement Using Cone Beam Computed Tomography

Details

Type

Article

Created At

22 Jan 2023