Aim: This study aimed to evaluate the insertion torque and initial stability of single thread implants versus double and triple thread implants.
Methods: Forty two osteotomies were prepared in fresh bovine bone. The implants used in this study were 3 types according to the thread lead design,single thread implant, double and triple thread implants (n=14). Implants were inserted in bone blocks until reaching insertion torques (30 Ncm, 40Ncm and 50Ncm) then calibration of the part of implant inserted within bone was performed. The primary stability was assessed via resonance frequency analysis using the Osstell ISQ device. The removal torque of each implant is measured at torque 50N/cm. intergroup and intragroup comparisons were performed. The significance level was set at p ≤ 0.05 for all tests.
Results: Regarding , implant insertion torque the highest value was found in single thread group followed by double thread group, while the lowest value was found in triple thread group. Primary stability results and removal torque revealed that, the highest value were found in triple thread group, followed by double thread group, while the lowest value were found in single thread group and there was a significant difference between different groups (p < 0.001) in all measured outcomes.
Conclusions: When primary stability is a concern, as in low bone quality, double and triple threaded implants can provide greater primary stability and insertion torque. Double threaded implants combine optimum insertion speed and high primary stability and insertion torque in compromised situations.

DOI

10.21608/edj.2021.59636.1590

Keywords

insertion torque, primary stability, Implant design, resonance frequency analysis, osstell device

Authors

First Name

Ayman

Last Name

Serag Eldeen

MiddleName

-

Affiliation

BDS, MSc, Faculty of Dentistry, Cairo University, Cairo, Egypt

Email

aymansoror1313@gmail.com

City

Egypt

Orcid

-

First Name

Hamdy

Last Name

Hamed

MiddleName

-

Affiliation

Professor of Removable Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt.

Email

hamdyaboulfotouh@gmail.com

City

-

Orcid

-

First Name

Hesham

Last Name

Fattouh

MiddleName

-

Affiliation

Assistant Professor of Oral and Maxillofacial Surgery, Faculty Dentistry, Cairo University, Cairo, Egypt.

Email

heshamfattouh2002@yahoo.com

City

-

Orcid

0000-0001-5404-8032

First Name

Mohammed

Last Name

Abdel Rasoul

MiddleName

-

Affiliation

Lecturer of Oral and Maxillofacial Surgery, Faculty of Dentistry, Cairo university, Cairo, Egypt

Email

mohammedatef@dentistry.cu.edu.eg

City

-

Orcid

0000-0003-4849-6626

Volume

67

Article Issue

3

Related Issue

26164

Issue Date

2021-07-01

Receive Date

2021-05-15

Publish Date

2021-07-01

Page Start

1,995

Page End

2,006

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_181483.html

Detail API

https://edj.journals.ekb.eg/service?article_code=181483

Order

11

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Evaluation of Insertion Torque and Initial Stability of Single Thread Implants versus Double and Triple Thread Implants: An Animal Study

Details

Type

Article

Created At

22 Jan 2023