Fracture incidence in implant retained mandibular overdenture constructed by either conventional method or CAD/CAM technology- A one year follow up.

Abstract
Purpose: To compare clinically the fracture incidence in overdentures constructed by CAD/CAM technology and compare it with those overdentures constructed by conventional heat cured methods in mandibular overdentures retained by two implants.
Materials and Methods: Twenty completely edentulous patients were participated in this study. The patients were randomly allocated to two equal groups of patients (Group A and group B). Group A patients received complete dentures constructed by conventional heat cured technique. Group B patients received complete dentures constructed by CAD/CAM technology. All the patients received two root form implants bilaterally in the canine regions following delayed loading protocol. Locator attachment was then used to retain the overdenture after 3 months healing period. Overdenture fracture was evaluated for the next 12 month after implant loading.
Results: Only two overdentures from the conventional overdenture group (group A) experienced fracture at area near to the abutment. Chi-square test indicted that, there is no significant differences in the fracture incidence between the study groups after 12 months observation period (P> 0.05).
Conclusion: The incidence of overdenture fractures was not significantly different between overdentures constructed by CAD/CAM or conventional heat curing techniques. When fractures take place, they tended to be in areas close to the abutment.

DOI

10.21608/edj.2021.51798.1376

Keywords

Implant overdenture, fracture, CAD/CAM

Authors

First Name

Mahmoud

Last Name

Aly

MiddleName

-

Affiliation

Lecturer of Prosthodontics, Faculty of Dentistry, Suez Canal University

Email

mahmouddent2006@hotmail.com

City

-

Orcid

0000-0003-3784-9633

Volume

67

Article Issue

2

Related Issue

23473

Issue Date

2021-04-01

Receive Date

2020-12-01

Publish Date

2021-04-01

Page Start

1,417

Page End

1,422

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_160107.html

Detail API

https://edj.journals.ekb.eg/service?article_code=160107

Order

9

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Fracture incidence in implant-retained mandibular overdenture constructed by either conventional method or CAD/CAM technology- A one year follow up.

Details

Type

Article

Created At

22 Jan 2023