Beta
144006

Stress analysis of two different attachments for a single implant retained mandibular overdentures in the midline (In vitro study)

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Abstract
Objective: aiming to record the induced micro-strain around one installed implant in the midline of a completely edentulous mandible using strain gauges utilizing an implant retained overdenture with two different types of attachments Ball and CMLOC attachment.
Materials and methods: An acrylic resin test resin test model representing a completely edentulous lower arch was used.. Duplication of the finished denture was carried out to be used as a surgical stent .A single implant installed in the midline. After the implant was installed in the acrylic resin cast, the ball attachment was screwed to the implant. The denture was prepared for the direct pick up procedure, the same procedure repeated for CM IOC attachment. Four strain gauges around were installed on all surfaces of implant to monitor the effect of the applied loads vertical on the two types of attachments. A vertically load applied of 100 N static load was applied by using universal testing machine at three different sites .
Results : When the load applied on the right side and left side ,it was shown that the single implant retained overdenture with ball the attachment has shown higher microstrain than the CMLOC
Conclusion: It can be concluded from this invitro study that the newly introduced attachment the CMLOC lends to show a better performance with regards to the micro-strains induced around the implants and also regarding improving the stability of the denture . On the other hand the ball attachments tends to show more micro-strain around the implants.

DOI

10.21608/edj.2020.49329.1332

Keywords

ball, attachments, CMLOC attachment

Authors

First Name

ahmed

Last Name

hasanin

MiddleName

-

Affiliation

Oral Implantology Department, Faculty of Dentistry Cairo University, Egypt

Email

hasa40741@gmail.com

City

cairo

Orcid

0000-0003-0440-0178

First Name

hamdi

Last Name

abo alfotouh

MiddleName

-

Affiliation

Removable Prosthodontics Department, Faculty of Dentistry Cairo University, Egypt

Email

hamdi.aboalfoutoh@gmail.com

City

cairo

Orcid

-

First Name

Nouran

Last Name

Abdel Nabi

MiddleName

-

Affiliation

Removable Prosthodontics Department, Faculty of Dentistry Cairo University, Egypt

Email

dr_nouran9834@gmail.com

City

cairo

Orcid

-

Volume

67

Article Issue

Issue 1 - January (Fixed Prosthodontics, Removable Prosthodontics and Dental Materials)

Related Issue

21309

Issue Date

2021-01-01

Receive Date

2020-11-09

Publish Date

2021-01-01

Page Start

689

Page End

697

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_144006.html

Detail API

https://edj.journals.ekb.eg/service?article_code=144006

Order

20

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Stress analysis of two different attachments for a single implant retained mandibular overdentures in the midline (In vitro study)

Details

Type

Article

Created At

22 Jan 2023