Beta
119883

Influence of CBCT Different Voxel Sizes on Soft Tissue Thickness Measurement

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objective: The aim of this study is to assess the effect of different CBCT voxel sizes on the soft tissue thickness measurements in a variety of maxillary and mandibular regions.
Methods: Two thicknesses (less than 2.0 mm and more than 2.0 mm) of pink baseplate wax as simulated soft tissue were overlaid on a maxilla and mandible of a dry human skull. The thicknesses were measured with a digital caliper as the physical measurements. The skull was scanned using CBCT with four different voxel sizes (0.20, 0.25, 0.30 and 0.4 mm). CBCT measurements were compared to the physical measurements. Intraclass Correlation Coefficient was used to assess both intra- and inter-observer reliability. Significance was considered to be 5% (P ≤ 0.05).
Results: Results showed a significant difference between the CBCT measurements using the 0.3 and 0.4 mm voxel sizes scans compared to the physical measurements when wax thickness was less than 2.0 mm. On the other hand, no significant difference was found for the CBCT measurements using the four voxel sizes when thickness was greater than 2.0 mm.
Conclusions: CBCT scans with voxel sizes of 0.3 mm and 0.4 mm provide accurate simulated soft tissue measurements when the thickness is more than 2.0 mm. However, when greater visualization of details are required, scans with lower voxel sizes is required. Therefore, in a clinical situation, it is of great importance to customize the resolution protocol according to the accuracy needed.

DOI

10.21608/edj.2020.42200.1252

Keywords

Cone beam computed tomography, soft tissue, voxel size

Authors

First Name

Raghdaa

Last Name

Mostafa

MiddleName

-

Affiliation

Oral and Maxillofacial Radiology, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Email

raghdaa.mostafa@asfd.asu.edu.eg

City

cairo

Orcid

-

Volume

66

Article Issue

Issue 4 - October (Oral Medicine, X-Ray, Oral Biology & Oral Pathology)

Related Issue

17990

Issue Date

2020-10-01

Receive Date

2020-09-08

Publish Date

2020-10-01

Page Start

2,401

Page End

2,409

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_119883.html

Detail API

https://edj.journals.ekb.eg/service?article_code=119883

Order

21

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Influence of CBCT Different Voxel Sizes on Soft Tissue Thickness Measurement

Details

Type

Article

Created At

22 Jan 2023