102931

Evaluation of Primary Stability in Immediate Non Submerged Root Analogue Zirconium Implants: A Preliminary Study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objective: The aim of the present study was to evaluate the primary stability of immediate,
custom made zirconium root analogue implant. Our 2ry outcome was to evaluate Marginal bone changes at the day of implantation, & after 3 months.
Patients and methods: This study included 8 immediate implant placements in fresh
sockets in esthetic zones using custom made zirconium implants. A Pre-operative CBCT was obtained for each patient to get the measurements & dimensions of the un-restorable teeth. Patients were prepped for the procedure under LA. Extraction of teeth was done atraumatically.
The extracted remaining roots were disinfected then mounted on the laser scanner to produce an stl.file of the remaining roots. Then using the CAD software to modify the root analogue by adding macro retentive “blebs" on the lateral surfaces of custom made zirconium implant. Transferring the design to the milling machine using zirconium blocks.
The implants were subjected to surface treatment using sand blasting method, & then sterilized. Patients were recalled after 3 days for insertion; and implantation using
tapping technique, to achieve primary stability. The primary stability was measured using
periotestM device as a primary outcome. Standardized paralleling technique was used to assure
the seating of the implant inside the socket after insertion, & for evaluation of the marginal bone changes as a 2ry outcome.
Results: All custom made zirconium implants failed to osseointegrate
Conclusion:Within the limitations of this study, the authors could not measure the stability nor
the marginal bone changes of custom made zirconium implants

DOI

10.21608/edj.2020.32794.1142

Keywords

custom-made zirconium dental implants, Primary implant stability, osseointegration, Root Analogue

Authors

First Name

Haytham

Last Name

Elkhouly

MiddleName

Ayman

Affiliation

Assistant Lecturer of Oral & Maxillofacial Surgery Department at MSA University

Email

dr.haytham.ayman@gmail.com

City

Cairo

Orcid

-

First Name

Nader

Last Name

Elbokle

MiddleName

Nabil

Affiliation

Professor of Oral & Maxillofacial Surgery Faculty of Dentistry Cairo University

Email

nbokle@samaclinic.com

City

Cairo

Orcid

-

First Name

Mohammed

Last Name

Khashaba

MiddleName

-

Affiliation

A. Professor of Oral & Maxillofacial Surgery Faculty of Dentistry Cairo University

Email

mohammedkhashaba@hotmail.com

City

Giza

Orcid

0000-0001-5632-2357

Volume

66

Article Issue

Issue 3 - ِJuly (Oral Surgery)

Related Issue

15560

Issue Date

2020-07-01

Receive Date

2020-06-17

Publish Date

2020-07-01

Page Start

1,509

Page End

1,518

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_102931.html

Detail API

https://edj.journals.ekb.eg/service?article_code=102931

Order

3

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Evaluation of Primary Stability in Immediate Non Submerged Root Analogue Zirconium Implants: A Preliminary Study

Details

Type

Article

Created At

22 Jan 2023