Beta
92743

INFLUENCE OF FINISH LINE DESIGN ON THE VERTICAL MARGINAL DISCREPANCY OF ENAMIC HYBRID CERAMIC: IN VITRO STUDY

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

-

Abstract

Aim of the study: The aim of this study was to evaluate the effect of finish line design (chamfer and shoulder) on the vertical marginal gap distance, and fracture resistance of Hybrid ceramic (Vita Enamic, VITA Zahnfabrik, Bad Sackingen, Germany). Materials and Methods: Two stainless steel dies were machine milled to simulate a tooth preparation for a ceramic crown of a mandibular second molar with two finish line configurations 1mm chamfer and 1 mm shoulder. Each die was 6-mm in height, 8-mm in cervical diameter, 6mm in occlusal diameter and had a total occlusal convergence of 16o. Digitalization of both dies and milling of hybrid restorations was made using CAD-CAM technology. Sixteen full coverage hybrid ceramic crowns were constructed from milled Vita Enamic hybrid ceramic blocks. The samples were divided into two equal groups' eight samples for each finish line tested.-Group Ac: eight samples (n=8) with Chamfer finish line.Group Bs: eight samples (n=8) with Shoulder finish line. All restorations were positioned onto a digital-microscope, magnification 50 X, and the images were captured and transferred to a IBM personal computer equipped with the Image-tool software to measure the vertical marginal gap distance. Results: The results showed a statistically significant difference between the two groups (Ac, Bs) where the mean values were (35.44μm and 48.36μm) respectively at p=0.002. Conclusions: the vertical marginal gap values of both finish line designs are within the clinically accepted range

DOI

10.21608/edj.2016.92743

Authors

First Name

Ashraf

Last Name

Dabbousi

MiddleName

Mohammad Ayman

Affiliation

B.D.S IUST University, Master Degree of Fixed Prosthodontics, Cairo University

Email

-

City

-

Orcid

-

First Name

Rabab

Last Name

Ibrahim

MiddleName

Mohammed

Affiliation

Professor of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University

Email

-

City

-

Orcid

-

First Name

Rana

Last Name

Sherif

MiddleName

Mahmoud

Affiliation

Associate Professor of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University

Email

-

City

-

Orcid

-

Volume

62

Article Issue

Issue 1 - January (Part 2)

Related Issue

13974

Issue Date

2016-01-01

Receive Date

2020-05-31

Publish Date

2016-01-01

Page Start

571

Page End

576

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_92743.html

Detail API

https://edj.journals.ekb.eg/service?article_code=92743

Order

31

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023