79356

Effect of different restor ative crowns on fracture resistance and stress distribution in single implants; An In-Vitro study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Statement of the problem. Implant failure due to poor biomechanical behavior is a common
problem in dentistry. Occlusal overloading is considered the primary cause of peri-implantitis,
implant and\or prosthesis fracture, and screw loosening or fracture.
Purpose. The purpose of this study was to investigate the effect of different restorative crowns
on the fracture resistance and stress distribution in single implants.
Materials and Methods. One implant was anchored in a measurement model based on a
real-life patient situation simulating (D3) bone density. Strain gauges (SGs) were fixed mesially,
distally, lingual and buccally adjacent to the implant. A total of 20 crowns were produced using a
CAD\CAM machine and divided into two equal groups according to the material type; Zirconia
and (PEEK) (n=10). The magnitude of strain was recorded in microstrains (με). Each specimen was
loaded to fracture in a universal testing machine with a crosshead speed of 0.5 mm/min. Data were
analyzed with 2-way univariate ANOVA and Tukey HSD test (α=.05).
Results. The mean strain values for the two groups at the different (SG) sites ranged from (26.0
to 1033.6 μm/m). The 2-way univariate ANOVA indicated statistically significant differences (P
<0.001) between the zirconia and the (PEEK) crowns .In addition, Mean (SD) failure loads were
2070.5(100.24) N for zirconia crowns, 950.75(34.61) N for (PEEK) crowns. The 2-way univariate
ANOVA showed a statistically significant difference for the fracture resistance between the zirconia
and (PEEK) crowns (P< 0.001).
Conclusions: Superstructure materials appear to have an influence on strain development in
single implant restorations.

DOI

10.21608/edj.2018.79356

Authors

First Name

Mazen

Last Name

Attia

MiddleName

A.

Affiliation

Lecturer of Fixed Prosthodontics, Faculty of Dentistry, Beni Suef University

Email

-

City

-

Orcid

-

First Name

Haitham

Last Name

Amr

MiddleName

-

Affiliation

Lecturer of Fixed Prosthodontics, Faculty of Dentistry, Fayoum University

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11458

Issue Date

2018-10-01

Receive Date

2020-03-28

Publish Date

2018-10-01

Page Start

3,813

Page End

3,822

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_79356.html

Detail API

https://edj.journals.ekb.eg/service?article_code=79356

Order

29

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect of different restor ative crowns on fracture resistance and stress distribution in single implants; An In-Vitro study

Details

Type

Article

Created At

22 Jan 2023