79243

Effect of splinting on the accuracy of impressions of multiple straight implants in full arch rehabilitation: An in vitro-study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objectives: This study was conducted to assess the effect of different splinting techniques
(with and without sectioning of the splinting material) on the accuracy of impressions of multiple
straight implants in full arch rehabilitation cases.
Materials and methods: A maxillary resin printed study model with five straight fixtures was
used as the master model. Open tray impression technique was done for all groups. Three groups
were defined according to splinting of the impression copings: Group A: Impression copings were
splinted to each other using autopolymerizing acrylic resin. Group B: Impression copings were
splinted to each other using autopolymerizing acrylic resin which was sectioned with a 0.3 mm
thickness disc and reconnected with a second mix of resin. Group C: Impression copings were not
splinted to each other. For each group, five different impressions were prepared. The impressions
were poured to create the casts that were digitally scanned. The accuracy of the positions and
angulations of the implants was evaluated using a computer-graphics coordinate measurement
system.
Results: Group A showed higher angular deviation compared to group B and group C. One way
ANOVA showed statistically significant difference between the studied groups, P value was <0.001.
However, Tukey post hock test showed statistically significant difference between group A and the
other groups and no statistically significant difference between group B and group C. On the other
hand, regarding linear deviation one way ANOVA showed no statistically significant difference
between the studied groups.
Conclusion: Both split acrylic‑splinted and non-splinted implant impression techniques yield
more accurate master casts regarding angular deviation compared to splinted impression technique
without splitting.
 

DOI

10.21608/edj.2018.79243

Keywords

Splinting, Implant impressions, accuracy of impressions

Authors

First Name

M.

Last Name

Nabhan

MiddleName

Shady

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry Ain Shams University.

Email

-

City

-

Orcid

-

First Name

Yasmine

Last Name

Thabet

MiddleName

G.

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry Ain Shams University.

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11458

Issue Date

2018-10-01

Receive Date

2020-03-26

Publish Date

2018-10-01

Page Start

3,733

Page End

3,739

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_79243.html

Detail API

https://edj.journals.ekb.eg/service?article_code=79243

Order

21

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect of splinting on the accuracy of impressions of multiple straight implants in full arch rehabilitation: An in vitro-study

Details

Type

Article

Created At

22 Jan 2023