Beta
79241

THE EFFECT OF MAGNETIC AND CM LOCK ATTACHMENTS ON STRAIN AROUND IMPLANTS RETAINED MANDIBULAR OVERDENTURE: A STRESS ANALY SIS STUDY

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objectives: This in-vitro strain gauge study was conducted to compare between magnetic and
CM lock attachments regarding strain induced around two implants supporting a mandibular over
denture.
Methodology: This study was performed using two implants 3.7mm x 12mm installed at the
canine area bilaterally in an acrylic model resembling a completely edentulous mandible. Pick
up of the magnetic and CM loc attachments was done followed by loading and measurements
respectively. The strain induced around the implants was evaluated during unilateral and bilateral
loading at the first molar area using a universal testing machine. Measurements were tabulated and
statistically analyzed.
Results: loading sides demonstrated significantly higher microstrains around the implants with
the two attachments than non-loading sides. CM LOC attachment showed significantly higher
microstrains than magnetic attachment for both loading and non-loading sides during unilateral
loading. During bilateral loading, a statistically significant higher mean micro strain was recorded
in the right implant than the left implant, CM lOC have shown a higher statistically significant mean
micro strain than the magnetic attachment for the right implant and no siginificant difference in the
left implant.
Conclusions: Within the limitation of this in-vitro study, it could be conclude that the attachment
type could have an effect on the amount of load that will be transmitted to the implants supporting
an over denture. Clinical studies are required to evaluate the effect of type of attachment on peri
implant crestal alveolar bone loss and correlate it with the results of the current study.
 

DOI

10.21608/edj.2018.79241

Keywords

In-vitro, Strain gauge analysis, magnetic attachment, CM lock attachment Over denture

Authors

First Name

Nada

Last Name

El khourazaty

MiddleName

-

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry, Cairo University.

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11458

Issue Date

2018-10-01

Receive Date

2020-03-26

Publish Date

2018-10-01

Page Start

3,723

Page End

3,731

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_79241.html

Detail API

https://edj.journals.ekb.eg/service?article_code=79241

Order

20

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

THE EFFECT OF MAGNETIC AND CM LOCK ATTACHMENTS ON STRAIN AROUND IMPLANTS RETAINED MANDIBULAR OVERDENTURE: A STRESS ANALY SIS STUDY

Details

Type

Article

Created At

22 Jan 2023