Beta
77271

Influence of Titanium Dioxide Incorporation on the Compressive Strength of Modified Calcium Silicate-Based Cement

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Aim: The aim of this investigation was to evaluate the effect of incorporating titanium dioxide (TiO2) particles on the compressive strength of modified calcium silicate-based cement (CSC).
Methods: The modified calcium silicate-based cement (CSC) used comprised 80 wt% white Portland-limestone cement and 20 wt% bisthmus oxide, as a radioopacifier. Incorporation of the 300-nm TiO2 particles was done in the following concentrations: 0% (CSC group), 1% (CSC + 1%TiO2 group), 3% (CSC + 3%TiO2 group) and 5% (CSC + 5%TiO2 group). Cylindrical specimens, 4 mm in diameter and 6mm in height, were prepared in split, teflon moulds; ten specimens were done for each group (n=10). Specimens were left to set for 7 days under wet conditions. Compressive strength testing was, then, done using an Instron testing machine. Data were analyzed using one-way analysis of variance (ANOVA) followed by Tukey post hoc test for pair-wise comparison. Statistical significance (α) was set at 0.05.
Results: There was no statistically significant difference among the four groups regarding compressive strength (p=0.162).
Conclusion: Within the conditions of this investigation, the incorporation of nano-scale TiO2 particles within a concentration range of 1 to 5 % does not seem to affect the compressive strength of the modified calcium silicate-based cement having white Portland- limestone cement as the main cementitious component.

DOI

10.21608/edj.2018.77271

Keywords

Calcium silicate-based cement, Titanium dioxide, Nanoparticles, limestone, Compressive strength

Authors

First Name

Suzan

Last Name

Amin

MiddleName

Abdul Wanees

Affiliation

Associate Professor, Department of Endodontics, Faculty of Dentistry, Cairo University.

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 3 - July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11454

Issue Date

2018-07-01

Receive Date

2020-03-13

Publish Date

2018-07-01

Page Start

2,737

Page End

2,745

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_77271.html

Detail API

https://edj.journals.ekb.eg/service?article_code=77271

Order

35

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Influence of Titanium Dioxide Incorporation on the Compressive Strength of Modified Calcium Silicate-Based Cement

Details

Type

Article

Created At

22 Jan 2023