77266

Periotest measurement of tooth- implant retained bi lateral mandibular distal extension removable prosthesis with ERA Attachments

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Aim: The aim of this study was to measure the stability of natural tooth and implant using periotest, in bilateral distal extension base, using ERA-ERA connection on one side and RPI-ERA on the other side.
Material and Methods: Ten patients with mandibular bilateral distal extension arches, with second premolar as last standing tooth, were selected for this study. Every patient received one implant placed distally at the region of the second molar bilaterally. The patients received removable prosthesis retained on one side by RPI while the other side received ERA attachment. Both implants were retained to the prosthesis using ERA attachment. Patients were evaluated for tooth and implant stability using Periotest at time of prosthesis insertion, after one month, three months and six months after insertion. The study was a split mouth design.
Results: Periotest measurements significantly decreased (increase in stability) with presence of ERA attachments on natural tooth and implants more than when the RPI was used on the natural tooth.
Conclusion: It can be concluded that the ERA attachments was more preservative for natural teeth periodontium than RPI clasp retainer. In addition, the stability of implant improved gradually by time.

DOI

10.21608/edj.2018.77266

Authors

First Name

Nancy

Last Name

El Sherbini

MiddleName

N

Affiliation

Lecturer Removable Prosthodontics, Faculty of Dentistry, Cairo University

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

El Sherbini

MiddleName

N

Affiliation

Lecturer Removable Prosthodontics, Faculty of Dentistry, MSA University.

Email

-

City

-

Orcid

-

First Name

Neidermeier

Last Name

W

MiddleName

-

Affiliation

Professor Prosthetic Depatment, Faculty of Dentistry, University of Cologne.

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 3 - July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11454

Issue Date

2018-07-01

Receive Date

2020-03-13

Publish Date

2018-07-01

Page Start

2,691

Page End

2,696

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_77266.html

Detail API

https://edj.journals.ekb.eg/service?article_code=77266

Order

31

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Periotest measurement of tooth- implant retained bi lateral mandibular distal extension removable prosthesis with ERA Attachments

Details

Type

Article

Created At

22 Jan 2023