Beta
77248

THE EFFECT OF THERMOCYCLING AND MECHANICAL LOADING ON THE FRACTURE RESISTANCE OF ALL-CERAMIC AND HIGH PERFORMANCE POLYMERS FIXED PARTIAL DENTURES

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Objectives: The purpose of this study was to evaluate the fracture resistance of the heat pressed ceramic (IPS e-max press) and the high performance polymers BioHPP anterior FPDs.
Materials and Methods A total number of 96 sound freshly extracted maxillary central incisors and canines were used in this study. The teeth were used to prepare a total of 48 three units FPD tested specimens. Specimens were used to test the fracture resistance of the materials under investigation without and after thermocycling and mechanical loading.
Results : The fracture load values of the IPS e-max specimens without TCML were ranged from 271.7 N to 206.01 N. While, after TCML the values were ranged from 171.6 N to 191.2 N. The fracture load values of the BioHPP specimens without TCML were ranged from 789.7 N to 665.1 N. While, after TCML the values were between 789.7 N and 615.4 N.
Conclusion: IPS e-max press FPDs had a lower fracture resistance than the BioHPP FPDs before and after TCML. The TCML decreased the resistance to fracture of both materials.

DOI

10.21608/edj.2018.77248

Keywords

IPS e-max, high performance polymers, Fracture resistance

Authors

First Name

Mohamed

Last Name

Mohamed

MiddleName

Mohey Eldin

Affiliation

Lecturer of Fixed Prosthodontics, Delta University For Science and Technology

Email

m.abdelrahman@tudent.edu.sa

City

-

Orcid

-

Volume

64

Article Issue

Issue 3 - July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11454

Issue Date

2018-07-01

Receive Date

2020-03-13

Publish Date

2018-07-01

Page Start

2,603

Page End

2,613

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_77248.html

Detail API

https://edj.journals.ekb.eg/service?article_code=77248

Order

23

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

THE EFFECT OF THERMOCYCLING AND MECHANICAL LOADING ON THE FRACTURE RESISTANCE OF ALL-CERAMIC AND HIGH PERFORMANCE POLYMERS FIXED PARTIAL DENTURES

Details

Type

Article

Created At

22 Jan 2023