78412

EFFECT OF DIAMETER AND BONE DENSITY ON IMPLANT STABILITY IN IMPLANT RETAINED MANDIBULAR OVERDENTURES

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objectives: This study was conducted to evaluate the effect of implant diameter and bone density on the stability of implants in implant retained overdentures.
Materials and methods: Totally, twenty-one patients with entirely edentulous upper and lower arches were randomly assigned into three groups (Group I, II, II). Group (I): patients are exhibiting type I (D1) bone density. Group (II): patients are exhibiting type II (D2) bone density. Group (III): patients are exhibiting type III (D3) bone density. In each patient, two implants with different diameters (3.5mm and 4 mm)were placed in the intra-foraminal region. Each patient received maxillary conventional complete denture and mandibular implant retained overdenture.Implant stability was measured at implant insertion and after three months.
Results: No statistically significant differences were detected regarding implant stability between groups with different bone densities and different diameters. Although there was an increase in implant stability after three months, differences between groups were statistically non-significant.
Conclusion: Within the limitations of this study, it was concluded that different implant diameters and bone densities don't have a significant influence on implant stability 

DOI

10.21608/edj.2018.78412

Authors

First Name

M.

Last Name

Nabhan

MiddleName

Shady

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry, Ain Shams University

Email

-

City

-

Orcid

-

First Name

Yasmine

Last Name

Thabet

MiddleName

G.

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry, Ain Shams University

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 2 - April (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11448

Issue Date

2018-04-01

Receive Date

2020-03-22

Publish Date

2018-04-01

Page Start

1,699

Page End

1,706

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_78412.html

Detail API

https://edj.journals.ekb.eg/service?article_code=78412

Order

34

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

EFFECT OF DIAMETER AND BONE DENSITY ON IMPLANT STABILITY IN IMPLANT RETAINED MANDIBULAR OVERDENTURES

Details

Type

Article

Created At