Abstract

Background: The Target of this study was to evaluate and analyze the changes that occur in the supporting structures of implants placed in the posterior mandibular region using the Immediate Functional Loading Protocol. The bone height of the four implant surfaces; buccal, lingual, distal and mesial were closely observed, measured and statistically analyzed.
Materials and Methods: Thirty implants were placed in ten patients with unmodified mandibular Kennedy Class II. For each patient, three implants were placed at the premolar/molar mandibular region. All the implants were immediately loaded following an Immediate Functional Loading Protocol. Radiographic evaluation using dental CT was carried out at intervals of 0, 12 and 24 months after implant surgery.
Results: Decrease in the bone level throughout the study period in the bucco-lingual surfaces however this decrease was statistically insignificant using paired t test. The same was found regarding the mesio-distal surface throughout the study period
Conclusion: Within the limitations of this study, it was found that immediately loaded single implants placed in the posterior mandibular area with high insertion torque is a favorable treatment option. Immediately loading protocol must be carefully done in patients with limited bucco-lingual bone width.

DOI

10.21608/edj.2018.78075

Keywords

immediate loading, functional loading, Computed tomography

Authors

First Name

Ahmed

Last Name

Sabet

MiddleName

Ezzat

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University

Email

-

City

-

Orcid

-

First Name

Heba

Last Name

khorshid

MiddleName

-

Affiliation

Department of Removable Prosthodontics, Faculty of Oral and dental medicine, Cairo University

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 1 - January (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11444

Issue Date

2018-01-01

Receive Date

2020-03-18

Publish Date

2018-01-01

Page Start

665

Page End

670

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_78075.html

Detail API

https://edj.journals.ekb.eg/service?article_code=78075

Order

36

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Immediate Functional Loading Effect on Supporting Structures of Implants placed in Mandibular Class II Kennedy Classification Cases. A Two Year Clinical Study

Details

Type

Article

Created At

22 Jan 2023