Beta
76463

THE EFFECT OF DIFFERENT ABUTMENT FINISH LINE CONFIGURATION ON STRESS DISTRIBUTION OF IMPLANT SUPPORTED ZIRCONIA FIXED PARTIAL DENTURE

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Purpose: to study the influence of different abutment finish line configuration on stress distribution of implant supported fixed partial denture.
Materials& Methods: Two endo-osseous screw vent implants for 2nd premolar and 2nd molar were chosen and placed parallel to each other. After resin model construction, Implants were attached to the corresponding abutments group according to the finish line configuration of the abutments. Group A: standard abutment with circular contour, Group B: anatomical abutment with anatomical contour. The fixed partial denture was designed with a flat area on the occlusal surface to accommodate for the loading pin tip each time. Strain gauges were adhered to four different sites (buccal, lingual, mesial and distal) and a force of 200N over 30 seconds duration and maintained for 30 seconds also. Then forces were removed and residual strains were released for 2 minutes.
Results: One-way ANOVA used to compare between different abutment finish line configuration and teeth for mean Strain (µm/m) and total strain followed by Tukey's post-hoc test for pairwise comparison. Significant level set at p < 0.05.The results revealed that all types of abutments have a certain level of misfit, which resulted in measurable strains. Significant difference was found between the different groups of the finish line configuration (standard & anatomical).
Conclusion: Difference in abutment finish line configuration may affect the stress pattern induced around dental implants.
Clinical significant: implant abutment with anatomical finish line configuration is a preferred selection for better stress distribution.

DOI

10.21608/edj.2017.76463

Keywords

anatomical abutment finish line, circular abutment finish line, Stress analysis, misfit

Authors

First Name

Aliaa

Last Name

Mahrous

MiddleName

-

Affiliation

Lecturer Fixed Prosthodontic Department, Faculty of Dentistry, Fayoum University, Egypt.

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11157

Issue Date

2017-10-01

Receive Date

2020-03-08

Publish Date

2017-10-01

Page Start

3,965

Page End

3,972

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_76463.html

Detail API

https://edj.journals.ekb.eg/service?article_code=76463

Order

66

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

THE EFFECT OF DIFFERENT ABUTMENT FINISH LINE CONFIGURATION ON STRESS DISTRIBUTION OF IMPLANT SUPPORTED ZIRCONIA FIXED PARTIAL DENTURE

Details

Type

Article

Created At

22 Jan 2023