Beta
76443

EFFECT OF PALATAL COVERAGE AND NUMBER OF MINI IMPLANTS USED TO ASSIST MAXILLARY OVERDENTURE: AN IN VITRO STUDY OF RETENTION, CYCLIC FATIGUE AND DEFORMATION OF MAXILLARY OVERDENTU

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Purpose : Prosthodontic complications related to implant assisted maxillary overdentures are reported more often. This in vitro study examined the influence of implant number and palatal coverage on retention, cyclic fatigue and denture base deformation of maxillary overdentures supported by five versus seven unsplinted mini implants.
Materials and methods: An edentulous model of maxillary arch with mini diameter implant dummies was fabricated. The implants were inserted into the anterior, premolar, and molar areas. Maxillary experimental dentures with complete and partial palatal coverage were fabricated. Cyclic dislodging forces were applied to assess cyclic fatigue and the resulting change in denture retention. Strain gauges were used to assess the deformation induced into the dentures when cyclic fatigue test was carried out on overdentures assisted by seven implants and five implants after excluding the posterior implants.
Results: Cyclic fatigue and denture base deformation induced in overdentures with partial palatal coverage assisted by five mini implants were significantly higher than overdentures with complete palatal coverage whether assisted by seven or five implants (P < .05). Overdentures with partial palatal coverage assisted by seven mini implants exhibited non-significant changes in retention, cyclic fatigue and base deformation when compared to overdentures with complete palatal coverage assisted by five mini implants.
Conclusion: Maxillary five mini implant assisted overdentures with partial palatal coverage revealed much higher cyclic fatigue and induced denture base deformation than overdentures with complete palatal coverage regardless of the mini implant number. With respect to retention, fatigue failure and denture deformation, maxillary seven mini implant assisted overdentures with partial palatal coverage exhibited no significant difference comparable to five mini implant assisted maxillary overdenture with complete palatal coverage.

DOI

10.21608/edj.2017.76443

Keywords

Mini implant, maxillary implants overdenture, partial palatal coverage, cyclic fatigue, deformation

Authors

First Name

Fatma

Last Name

El-Waseef

MiddleName

A.

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry, Mansoura University

Email

-

City

-

Orcid

-

First Name

Amira

Last Name

Gomaa

MiddleName

M.

Affiliation

Assistant professor of Removable Prosthodontics, Faculty of Dentistry, Mansoura University

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11157

Issue Date

2017-10-01

Receive Date

2020-03-08

Publish Date

2017-10-01

Page Start

3,783

Page End

3,798

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_76443.html

Detail API

https://edj.journals.ekb.eg/service?article_code=76443

Order

48

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

EFFECT OF PALATAL COVERAGE AND NUMBER OF MINI IMPLANTS USED TO ASSIST MAXILLARY OVERDENTURE: AN IN VITRO STUDY OF RETENTION, CYCLIC FATIGUE AND DEFORMATION OF MAXILLARY OVERDENTURE BASE

Details

Type

Article

Created At

22 Jan 2023