Beta
76438

STRESS ANALYSIS EVALUATION OF COMBINING RESILIENT ATTACHMENTS WITH DIFFERENT CANTILEVER BAR LENGTH ON SUPPORTING STRUCTURES OF IMPLANT SUPPORTED OVERDENTURE IN-VITRO STUDY

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Four screw type implants(Pitt-easy Implant System, SIS, Germany) were placed in the interforaminal region of mandibular acrylic model then the abutments(Titanium sleeve abutment,Pitt –easy, Germany) intimately fitted over the hex of the implant. Two bar-ball designs were constructed on single model; Design I: Bar with yellow colored clips(Vario- Soft bar- Pattern VSP) connecting four implants with 8 mm distal cantilever bar extension with distally placed ball attachment (Patrix VKS - SG,Bredent,Germany) Design II: Bar with yellow clips connecting four implants with 16 mm distal cantilever with distally placed ball attachment. Two bar-ball designs were constructed on single model as follow: The bar connecting the abutments were held with mandrel, so that it's rounded surface facing occlusally and its flat surface facing to the ridge. The wires of the strain gauges(Kaywan, Electronic Instrument, Tokyo, Japan) were embedded in specially prepared channels in the base of the model. The straight load applicator bar of the universal testing machine(LLyod Instruments, Japan) was allowed to touch the denture teeth. Vertical unilateral loading was applied unilaterally at the central fossae of the left second premolar.All data of the study were collected and statistically analyzed. Using student T test to compare between two designs, it is found that there is statistically significant difference between design I and design II. The result obtained from this study showed that there is increase in the stresses applied to the nearby abutment this was due to the distal extension that act as hidden cantilever which add to bending moment and the fact that in design II the bending moment will decrease, thus decreasing the amount of force on the abutment. 

DOI

10.21608/edj.2017.76438

Authors

First Name

Ahmed

Last Name

Mahrous

MiddleName

Ibrahim

Affiliation

Lecturer of Removable Prosthodontics , Faculty of Dentistry, October 6 University. Egypt

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11157

Issue Date

2017-10-01

Receive Date

2020-03-08

Publish Date

2017-10-01

Page Start

3,725

Page End

3,730

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_76438.html

Detail API

https://edj.journals.ekb.eg/service?article_code=76438

Order

43

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

STRESS ANALYSIS EVALUATION OF COMBINING RESILIENT ATTACHMENTS WITH DIFFERENT CANTILEVER BAR LENGTH ON SUPPORTING STRUCTURES OF IMPLANT SUPPORTED OVERDENTURE IN-VITRO STUDY

Details

Type

Article

Created At

22 Jan 2023