Beta
76427

CURING EFFECTIVENESS OF NANOFILLED RESIN COMPOSITE USING DIFFERENT LED CURING INTENSITIES AT DIFFERENT IRRADIATION TIME

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

-

Abstract

Aim: evaluated the effectiveness of different LED curing light intensities at different irradiation time on the microhardness and depth of cure (hardness ratio) of nanofilled resin composite material.
Materials and methods: Nanofilled resin composite material (Filtex Z350XT, 3M, ESPE) and LED curing unit (Dr's light AT, Good doctors co.ltd. korea) with two different light intensities were used in this study. Two Circular Teflon moulds with two different thickness were used to prepare 25Resin composite discs specimen that were divided into five groups (5 discs each). For group 1, 2mm thick resin composite disc specimens where polymerized using standard light curing intensity (800 mW/cm2) for 30 sec. while for group 2, 4mm thick resin composite disc specimens where polymerized using standard light curing intensity (800 mW/cm2) for 30 sec. group 3, 2mm thick resin composite disc specimens where polymerized using high intensity light curing mode (1400 mW/cm2) for 10 sec. group 4, 4mm thick resin composite disc specimens where polymerized using high intensity light curing mode (1400 mW/cm2) for 10 sec. Group 5, 4mm thick resin composite disc specimens where polymerized using high intensity light curing mode (1400 mW/cm2) for 20 sec. Microhardness testing was performed and the mean microhardness values and hardness ratio % of the specimens were calculated, tabulated and statistically analyzed using independent (unpaired) t test for 2 groups comparisons while one way analysis of variance (ANOVA) and Tukey post hoc tests were used to study the significance between more than 2 groups. The significance level was set at p ≤ 0.05. Statistical analysis was performed with SPSS 19.0
Results: The highest mean value was recorded in group 5: 4mm thick disc specimens cured with high intensity for 20 sec (91.16%), whereas the lowest mean was recorded in group 4: 4mm disc specimens cured with high intensity for 10 sec (73.34%). A significant difference was found between both groups (p=0.032). However, no significant difference was detected between group 3: High 10 (2mm) that recorded 85.56% , group 5: High 20 (4mm) recording 91.16% and group 1 and 2: standard ( 2mm and 4mm respectively) recording 86.96% and 81.08% respectively.
Conclusions: 1. Depth of cure and microhardness values were greatly affected by the interaction between curing light intensities and irradiation time and material thickness as well. 2. Nanofilled resin composites irradiated with LED high light intensity (1400 mW/cm2) for 20 sec. demonstrated a higher microhardness. 3. Composites might be cured in increments higher than 2 mm and up to 4mm when using LED high intensity light curing system with special caution to the irradiation time applied.

DOI

10.21608/edj.2017.76427

Keywords

nanofilled composite, depth of cure, LED, light intensities, microhardness ratio

Authors

First Name

Shereen

Last Name

Hafez

MiddleName

-

Affiliation

Lecturer of Conservative Dentistry, Faculty of Dentistry, Cairo University

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11157

Issue Date

2017-10-01

Receive Date

2020-03-08

Publish Date

2017-10-01

Page Start

3,625

Page End

3,631

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_76427.html

Detail API

https://edj.journals.ekb.eg/service?article_code=76427

Order

32

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023