76224

THE EFFECT OF MAGNETIC AND LOCATOR ATTACHMENTS ON STRAIN AROUND IMPLANTS RETAINING MANDIBULAR OVERDENTURE: AN IN VITRO STUDY

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objectives: This in-vitro strain gauge study was conducted to compare between magnetic and locator attachments regarding strain induced around two implants supporting a mandibular overdenture.
Methodology: The study was performed on acrylic models of a completely edentulous mandibular arch with two implants installed bilaterally at the canine areas. The strain induced around the implants was studied during unilateral and bilateral loading at the first molar area using a universal testing machine.
Results: The results of this study showed that there was no statistically significant difference between the two studied groups during unilateral loading with higher values in the locator attachment group while during bilateral loading there was a statistically significant difference between the two groups but with higher micro-strain values for the magnetic attachment group
Conclusion: Within the limitation of this in-vitro study, it could be conclude that the attachment type could have an effect on the amount of load that will be transmitted to the implants supporting an over denture. Clinical studies are required to evaluate the effect of type of attachment on peri-implant crestal alveolar bone loss and correlate it with the results of the current study.

DOI

10.21608/edj.2017.76224

Keywords

In-vitro study- Strain gauge analysis-magnetic attachment- locator attachment-Overdenture

Authors

First Name

Ahmed

Last Name

Fayyad

MiddleName

-

Affiliation

Lecturer of Prosthodontics, Faculty of Dentistry, Cairo University

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 3 - July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11153

Issue Date

2017-07-01

Receive Date

2020-03-07

Publish Date

2017-07-01

Page Start

2,661

Page End

2,669

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_76224.html

Detail API

https://edj.journals.ekb.eg/service?article_code=76224

Order

22

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

THE EFFECT OF MAGNETIC AND LOCATOR ATTACHMENTS ON STRAIN AROUND IMPLANTS RETAINING MANDIBULAR OVERDENTURE: AN IN VITRO STUDY

Details

Type

Article

Created At

22 Jan 2023