76060

Accuracy of Linear Measurements in Stitched Cone Beam Computed Tomographic Images An In-Vitro Stud

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Introduction: Cone Beam Computed Tomography plays a major role in all specialties of maxillofacial region. This variability in applications necessitates variability in the available Field of View (FOV). However, large detector size might not be available in some machines. Stitching allows the fusion of 2 or more small volumes to form larger volumes. For that this study was carried out to evaluate the accuracy of linear measurements obtained from stitched CBCT images compared to direct real measurements.
Methodology: Twenty four skulls with mandibles were recruited from Anatomy Department, Faculty of Medicine, Cairo University. Two radiopaque gutta percha markers were glued on each skull and mandible at the nasion and mental ridge (at mid line) respectively. Each skull fixed to its mandible was placed on the CBCT machine Planmeca Pro Max 3D Mid® (Asentajankatu, Helsinki, Finland) in Oral and Maxillofacial Radiology Department at Faculty of Dentistry, Cairo University. For real measurements, the distance between the two markers was measured using digital caliper. The resultant images were evaluated using Planmeca Romexis Viewer version 4.4.0.R (Asentajankatu, Helsinki, Finland) and the CBCT measurements were performed by two blinded observers.
Results: The mean real measurement was 96.12 (±11.42) mm which was slightly greater than that of the CBCT measurement which is 95.43 (±11.39) mm. There was a good agreement between CBCT and real measurements. The level of inter-observer and intra-observer agreement is very strong regarding both real and CBCT measurements
Conclusion: Linear measurements driven from Stitched CBCT images are accurate and reliable for diagnostic purposes in maxillofacial region.

DOI

10.21608/edj.2017.76060

Keywords

linear measurements, Stitching, Stitched CBCT

Authors

First Name

Ahmed

Last Name

Abd Alsamad

MiddleName

M.

Affiliation

Lecturer of Oral and Maxillofacial Radiology, Faculty of Dentistry, Cairo University

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 3 - July (Oral Medicine, X-Ray, Oral Biology & Oral Pathology)

Related Issue

11152

Issue Date

2017-07-01

Receive Date

2020-03-07

Publish Date

2017-07-01

Page Start

2,435

Page End

2,440

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_76060.html

Detail API

https://edj.journals.ekb.eg/service?article_code=76060

Order

16

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Accuracy of Linear Measurements in Stitched Cone Beam Computed Tomographic Images An In-Vitro Stud

Details

Type

Article

Created At

22 Jan 2023