75177

A CORRELATION BETWEEN IMPLANT STABILITY AND BONE HEIGHT MEASUREMENTS AFTER A ONE YEAR FOLLOW UP

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Background: Implant stability and bone height measurements have been identified as an important criteria for maintaining and achieving successful Osseo integration. Resonance frequency analysis (RFA) under the brand name of Osstell has been used to monitor implant stability during the various follow ups of clinical research owing to its high reproducibility. Cone beam CT (CBCT), recently has proved to be a valuable tool to detect bone height measurements in 3dimensions.
Materials and Methods: Three implants were installed in the mandibular inter-formainal region of ten completely edentulous patients. After three month from implant installation patients were divided randomly into two groups; ball attachment and locator attachment. Implant stability was recorded for all patients initially during implant installation and at the day of delivery of the attachment, then after 12 month follow up. CBCT was made for all patients at the day of loading and then after 12 month follow up period. A correlation between the ISQ values of all implants in both groups of patients and bone height measurements was made after a 12 month follow up.
Results: After a one year follow up, there was a significant poor positive correlation r =0.114, p (2-tailed) ≤0.001, between implant stability recorded using the Osstell (RFA), and bone height measurements recorded from CBCT.
Discussion: Osstell has proven to be used as a reliable tool for measuring the stiffness of bone –implant contact. An increase in the Osstell readings (ISQ values), would indicate an increase in implant stability during the different follow up intervals. Additionally, an increase in bone height measurements from CBCT, will indicate an increase in the amount of bone to implant contact. When correlating the implant stability values and the bone height measurements, a poor positive correlation was detected, indicating that over a one year follow up, an increase in implant stability (ISQ value) will be accompanied by an increase of bone to implant contact.

DOI

10.21608/edj.2017.75177

Authors

First Name

Nouran

Last Name

Abdel Nabi

MiddleName

-

Affiliation

Lecturer in The Prosthodontic Department Cairo University

Email

-

City

-

Orcid

-

First Name

Heba

Last Name

Khorshid

MiddleName

-

Affiliation

Lecturer in The Prosthodontic Department Cairo University

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 2 - April (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11149

Issue Date

2017-04-01

Receive Date

2020-03-03

Publish Date

2017-04-01

Page Start

1,965

Page End

1,971

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_75177.html

Detail API

https://edj.journals.ekb.eg/service?article_code=75177

Order

37

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

A CORRELATION BETWEEN IMPLANT STABILITY AND BONE HEIGHT MEASUREMENTS AFTER A ONE YEAR FOLLOW UP

Details

Type

Article

Created At

22 Jan 2023