Beta
75168

CHEWING EFFICIENCY OUTCOME OF USING A SOFT LINER WITH IMPLANT RETAINED LOWER SINGLE COMPLETE OVER DENTURE

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Purpose: The aim of this study was to evaluate the effect of using a soft liner with locator attachment retained lower single complete over denture on the chewing efficiency.
Methodology: Seven patients aged 55-65 year had completely edentulous mandible opposing dentulous maxilla were selected for this study. All patients received a lower single complete over denture constructed over two implants, placed at the canine region and retained with locator attachment. After 3 months of denture using, the patient underwent soft lining of their overdenture. Chewing efficiency was evaluated three months after wearing denture without a soft liner (first measurement) and 3 months again after wearing the relined denture (second measurement) using the two colored chewing gum mixing ability test.
Results: There were statistically significant lower mean scores of the unmixed fraction of chewing gum value for all the chewing cycles of patients wearing lower single complete implant retained overdenture with locator attachment and soft liner compared to scores obtained with those patients wearing overdenture without a soft liner.
Conclusion: Using a soft liner with mandibular single complete overdenture that retained with locator attachment improves the chewing efficiency.

DOI

10.21608/edj.2017.75168

Keywords

Single mandibular complete denture –Implant retained over denture- Locator attachment-Soft liner

Authors

First Name

Faten

Last Name

Abu Taleb

MiddleName

A.S,

Affiliation

Assistant Prof of Removable Prosthodontics, Prosthodontic Department, Faculty of Dentistry, Tanta University

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 2 - April (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11149

Issue Date

2017-04-01

Receive Date

2020-03-03

Publish Date

2017-04-01

Page Start

1,931

Page End

1,938

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_75168.html

Detail API

https://edj.journals.ekb.eg/service?article_code=75168

Order

34

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

CHEWING EFFICIENCY OUTCOME OF USING A SOFT LINER WITH IMPLANT RETAINED LOWER SINGLE COMPLETE OVER DENTURE

Details

Type

Article

Created At

22 Jan 2023