Beta
75143

MASTICATORY PERFORMANCE AND BITE FORCE EVALUATION IN COMPLETELY EDENTULOUS PATIENTS REHABILITATED WITH DIFFERENT THERMOPLASTIC DENTURE BASE MATERIALS

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objective: This study was conducted to evaluate the masticatory performance and bite force in complete denture wearer rehabilitated with thermoplastic nylon and thermoplastic acrylic resin denture base.
Methods: This study was done in out patients clinics, Faculty of Dental Medicine, Al- Azhar University. Masticatory performance and maximum bite force were evaluated in randomly selected forty completely edentulous patients. The patients were randomly allocated into two equal groups. Group I: Patient received a thermoplastic acrylic complete denture. (Polyan IC TM bredent GmbH & Co.KG, Germany). Group II: Patient received a thermoplastic nylon complete denture. (Vertex™ ThermoSens, Vertex-Dental B.V. Netherlands). Masticatory performance and maximum bite force measurements were taken one week after new denture placement and after six months of denture use. Statistics were analyzed using Independent t-test to compare the masticatory performance and maximum bite force measurements between both groups.
Results: After one week of new denture placement, there were no significance differences in masticatory performance and maximum bite force measurements between both groups. Masticatory performance and maximum bite force were increased considerably after six months of denture use. The masticatory performance and maximum bite force values were considerably higher in patients with a thermoplastic nylon denture than patients with thermoplastic acrylic denture with statistical significant difference after six months of denture use.
Conclusion: After six months of denture use, patients with a thermoplastic nylon denture have a higher masticatory performance and biting force than patients with a thermoplastic acrylic denture. Therefore, thermoplastic nylon denture could be used in management of completely edentulous patients with diminished masticatory performance bite force.

DOI

10.21608/edj.2017.75143

Keywords

Masticatory performance, bite force, Denture base materials, thermoplastic denture base

Authors

First Name

Mostafa

Last Name

Fayad

MiddleName

I

Affiliation

Assistant Professor of Removable Prosthodontics , Faculty of Dental Medicine, Al- Azhar University; Associate Professor, Prosthodontic Department, College of Dentistry,Taibah University, Saudi Arabia.

Email

-

City

-

Orcid

-

First Name

Nehad

Last Name

Harby

MiddleName

-

Affiliation

Assistant Professor, Prosthodontic Department, College of Dentistry, Sattam Bin Abdulaziz University, Saudi Arabia. Lecturer, Removable Prosthodontic Department, Faculty of Dental Medicine, Al- Azhar University.

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 2 - April (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11149

Issue Date

2017-04-01

Receive Date

2020-03-03

Publish Date

2017-04-01

Page Start

1,861

Page End

1,869

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_75143.html

Detail API

https://edj.journals.ekb.eg/service?article_code=75143

Order

27

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

MASTICATORY PERFORMANCE AND BITE FORCE EVALUATION IN COMPLETELY EDENTULOUS PATIENTS REHABILITATED WITH DIFFERENT THERMOPLASTIC DENTURE BASE MATERIALS

Details

Type

Article

Created At

22 Jan 2023