Beta
75255

STRESS ANALYSIS OF REMOVABLE PARTIAL DENTURES OF DISTAL EXTENSION CASES FABRICATED OF TWO RECENT AESTHETIC CAD/CAM PROSTHETIC MATERIALS VERSUS CONVENTIONALLY MANUFACTURED METALLI

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Recently, there are different types of esthetic materials used for RPDs framework fabrication some of which are applicable for CAD/CAM system. Distal extension base removable partial dentures exhibit composite type of support, which leads to movement of the denture base under load application and transmission of high amount of stresses to the supporting structures.
Aim: The current study was conducted to analyze the stress transmitted to the abutment teeth and the residual ridge by three types of RPDs of different materials; Conventionally manufactured metallic Co-Cr RPDs, and two thermoplastic RPD materials; Acetal (Polyoxymethylene; POM) and a modified PEEK (Poly-Ether-Ether-Ketone) material (BioHPP; Biocompatible high performance polymer) distal extension RPD frameworks both manufactured by computer aided design and computer aided manufacturing (CAD/CAM) system as two esthetic prosthetic materials.
Methods: Strain gauge technology was used to assess micro-strains induced to the denture supporting structures for the three fabricated RPDs groups. Master casts of ten patients with mandibular bilateral distal extension (the remaining teeth extending from left 1st premolar to right 1st premolar) were used so that each cast was duplicated into 4 casts; three of these casts were used for manufacturing of acetal and BioHPP frameworks by CAD/CAM system, and conventional Co-Cr RPD frameworks. The fourth cast was duplicated to obtain acrylic cast with movable acrylic abutment teeth over which the three RPDs (two metal-free and one metallic RPDs) of each case were seated and tested. The microstrain of the supporting structures was recorded on bilateral and unilateral loading.
Results: On bilateral loading: Mean value of microstrains recorded at the abutments was -63.75 and -18.75 at the ridge for Co-Cr group; For acetal group, it was -91.25 at the abutments and 18.94 at the ridge; For BioHPP group, microstrain was -106 at abutments, while it was 37.15 at the ridges. On unilateral loading: For Co-Cr group, microstrains recorded at right abutment was -52, while it was -6 at left abutment, and at right ridge it was -16.5 and -2 at left ridge; For acetal group, microstrains recorded at right abutment was -176 and -10 at left abutment, and at right ridge it was 17 and 4.5 at left ridge; For BioHPP group, microstrains recorded at right abutment was -284, while it was 10.5 at left abutment, and at right ridge it was 50.5 and 6.5 at left ridge.
Conclusion: Co-Cr RPDs group showed the least stresses transmitted to the supporting tissues followed by Acetal RPDs, while BioHPP RPDs group showed the highest mean values of microstrain induced to the abutment teeth and the residual ridge.

DOI

10.21608/edj.2017.75255

Keywords

Distal extension RPDs-Metal-free dentures-Acetal-BioHPP- Co-Cr-CAD/CAM-Stress analysis

Authors

First Name

Elsayed

Last Name

Eid

MiddleName

Gad

Affiliation

-

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 1 - January (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11145

Issue Date

2017-01-01

Receive Date

2020-03-03

Publish Date

2017-01-01

Page Start

1,003

Page End

1,017

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_75255.html

Detail API

https://edj.journals.ekb.eg/service?article_code=75255

Order

33

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

STRESS ANALYSIS OF REMOVABLE PARTIAL DENTURES OF DISTAL EXTENSION CASES FABRICATED OF TWO RECENT AESTHETIC CAD/CAM PROSTHETIC MATERIALS VERSUS CONVENTIONALLY MANUFACTURED METALLI

Details

Type

Article

Created At

22 Jan 2023