Statement of Problem: Prediction of primary implant stability is important before surgery to determine the possibility of immediate loading.
Purpose: To evaluate the predictability of primary implant stability from cortical bone thickness and bone density values of cone bone beam computed tomography (CBCT).
Material and Methods: 10 completely and partially edentulous patients were
thickness and bone density, was investigated using Pearson's correlation and multiple regression analysis.
Results: The regression model accounted for 61.5% of the variations in the implant stability with an insignificant impact (p value=014). Age was found to be the only variable that has a significant impact on implant stability with a coefficient correlation of ā€“ 0.47 and a p value of 0.03. Conclusions: Within the limitations of this study neither cortical bone thickness nor bone density obtained from a CBCT can predict primary implant stability. On the contrary, age seems to have a significant impact on the primary implant stability.
Clinical implications: CBCT does not seem to be a valuable tool for predicting the primary implant stability. Bone density and thickness readings should be interpreted with cautions.

DOI

10.21608/edj.2017.75022

Keywords

Primary implant stability, bone thickness, bone density, Age, correlation study

Authors

First Name

Iman

Last Name

Radi

MiddleName

AW

Affiliation

Associate Professor of Prosthodontics, Member of the Evidence Based Committee, Faculty of Oral and Dental Medicine, Cairo University.

Email

iman.abdelwahab@dentistry.cu.edu.eg

City

-

Orcid

-

First Name

Nouran

Last Name

Abdel-Nabi

MiddleName

-

Affiliation

Lecturer of Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University.

Email

-

City

-

Orcid

-

Volume

63

Article Issue

Issue 1 - January (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

11145

Issue Date

2017-01-01

Receive Date

2020-03-02

Publish Date

2017-01-01

Page Start

739

Page End

746

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_75022.html

Detail API

https://edj.journals.ekb.eg/service?article_code=75022

Order

4

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

PREDICTABILITY OF PRIMARY IMPLANT STABILITY FROM CORTICAL BONE THICKNESS AND BONE DENSITY VALUES OF CONE BEAM COMPUTED TOMOGRAPHIC SCANS: A CROSS SECTIONAL STUDY

Details

Type

Article

Created At

22 Jan 2023