Beta
75991

Effect Of Polyetheretherketone (PEEK) As Denture Base Material On Peri-Implant Bone Level Changes In Implant Bar Retained Overdenture Using CAD/CAM Technology

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objectives: This research was carried out to evaluate the effect of Polyetheretherketone (PEEK) as denture base material on peri-implant crestal bone level changes in edentulous patients rehabilitated with implant-supported primary-secondary bar overdenture and retained attachments attached the body of the bar constructed by CAD / CAM technology.
Materials and Methods: Twenty completely edentulous patients complaining from insufficient retention of their mandibular denture were selected to participate in this study. All the patients were rehabilitated with an implant-supported bar overdenture. For All patients three implants (3.7mm) in diameter (11mm) in length were inserted in the interforamenal region using computer guided surgical template. Four months later, Cast bar with two semi precession attachment at the distal ends of the bar was constructed, The cast bar was scanned using bench laser scanner to obtain virtual model with the bar, the housing on the top of the bar and the female part of the attachment was designed using computer aided designing (CAD) the meld into wax by computer aided manufacturing (CAM). The CAD/ CAM wax pattern of housing and the female part of the attachments were transferred into acetal resin using the injection molded technique. Overdentures were constructed for all patients following the conventional technique. According to the denture base material, a toss coin was made to randomly divided the patients into two equal groups; group I received mandibular implant-retained overdenture were processed using heat cured acrylic resin, following the long curing cycle (heated at 78C° for eight hours), while for
group II Polyetheretherketone (PEEK) lower overdenture was constructed, using the injection-molding technique. Radiographic evaluation of peri-implant bony changes was made using standardized long cone paralleling technique with custom made acrylic template and the Rinn-xcp at insertion, six, twelve and twenty four months were measured and statistically analyzed. The significant level was set at P ≤ 0.05P . ANOVA for repeated measures test was used to compare between follow up periods within groups and when statistically significant it was followed by simple main effect analysis with Bonferioni correction. One way ANOVA test was used to compare between groups at different follow up periods. Results. Both groups showed a statistically insignificant increase loss in crestal bone height around the implants. Although the data obtained from table1 revealed increase in the amount of bone changes for group I and Group II compared to group I during the follow up period statistical analysis of the data using ANOVA test for repeated measures revealed no significance difference(P ≥ 0.05) .
Conclusion: CAD/ CAM technology and use of Polyetheretherketone (PEEK) as denture base material should be considered whenever possible to preserve the implant supporting structures in implant bar retained overdenture.

DOI

10.21608/edj.2019.75991

Authors

First Name

Hesham

Last Name

Alameldeen

MiddleName

E.

Affiliation

Associate Professor of Prosthodntics, Faculty of Dentistry, Future University

Email

-

City

-

Orcid

-

First Name

Sahar

Last Name

Abdelbary

MiddleName

K.

Affiliation

Associate Professor of Prosthodntics, Faculty of Dentistry, Misr University for Science and Technology

Email

sahar_khalaf9@yahoo.com

City

-

Orcid

-

Volume

65

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10707

Issue Date

2019-10-01

Receive Date

2020-03-06

Publish Date

2019-10-01

Page Start

3,643

Page End

3,652

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_75991.html

Detail API

https://edj.journals.ekb.eg/service?article_code=75991

Order

9

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect Of Polyetheretherketone (PEEK) As Denture Base Material On Peri-Implant Bone Level Changes In Implant Bar Retained Overdenture Using CAD/CAM Technology

Details

Type

Article

Created At