Objective: This study was conducted to evaluate the crestal bone height changes of immediately loaded Porous trabecular tantalum dental implants (PTTM ) and screw shaped titanium implants in mandibular two implant overdenture with CBCT scan. Subjects & Methods: Fourteen completely edentulous patients were rehabilitated with maxillary complete dentures & immediately loaded mandibular two implant overdentures. Patients were selected according to certain inclusion & exclusion criteria. Conventional maxillary & mandibular complete dentures were constructed for all patients. Patients were then randomly divided into two equal groups according to the implant type. Group (I-Intervention Group): TM implants & Group (II- control Group): Conventional titanium Screw implants were utilized. Implants were installed in the mandibular interforaminal region. Implants were immediately loaded with ball retained overdentures. Radiographic Evaluation of crestal bone height changes around the implants was made with CBCT scan; at the denture insertion visit, 6, 12 , & 24 months after denture insertion. Data were collected, tabulated & statistically analyzed. Results: All patients were satisfied with their implant overdentures, No implant loss were recorded during the follow-up Period. The results of this study had revealed that the crestal bone height gradually decreased throughout the study period in the two studied groups. The mean values of crestal bone loss were (0.497mm± 0.161, 0.362mm ±0.045, 0.120mm.±0.13, 0.9 mm±0.67) and (0.65mm± 0.076 , 0.338mm±0. 047, 0.75 ±0.407, 1.20 ±0.108) in group I & Group II respectively at 0-6 month, 6- 12 month, 12- 18 month and from 0-24 month intervals. On comparing the studied Groups: The crestal bone loss was greater in Group (II) than Group (I) along the whole follow-up intervals. In the 1st & 2nd follow -up intervals; (0-6month & 6-12 Months) bone loss was greater in Group (II) than Group- I with statistically insignificant difference (P-values 0.069 ns &0.400 ns respectively). However, in the 3rd interval (6-12months) & (12-18 months) and( 0-24months), bone loss was significantly higher in Group-II than Group-I; with (P=0.000*). Conclusions: Within the limitation of the current study: Trabecular Tantalum Dental Implants (PTTM) may induce less crestal bone loss than conventional screw-shaped titanium implants in immediately loaded mandibular implant overdentures.

DOI

10.21608/edj.2019.75975

Authors

First Name

Azza

Last Name

Farahat

MiddleName

M.

Affiliation

Associate Professor in Removable Prosthodontics, Department, Faculty of Dentistry, Cairo University

Email

-

City

-

Orcid

-

First Name

Noha

Last Name

Nawar

MiddleName

H.

Affiliation

Associate Professor in Removable Prosthodontics, Department, Faculty of Dentistry, Ain Shams University

Email

-

City

-

Orcid

-

Volume

65

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10707

Issue Date

2019-10-01

Receive Date

2020-03-06

Publish Date

2019-10-01

Page Start

3,571

Page End

3,580

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_75975.html

Detail API

https://edj.journals.ekb.eg/service?article_code=75975

Order

1

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Comparative study of bone height changes around immediately loaded porous tantalum parallel sided Trabecular & Screw shaped implants retaining mandibular implant- overdentures using CBCT (RCT)

Details

Type

Article

Created At

22 Jan 2023