Beta
72667

A Comparison of microbial flora in peri-implant sulcular fluid of ball versus locator retained mandibular implant overdentures. A randomized crossover study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Purpose: To evaluate the microbial flora in peri-implant sulcular fluid of edentulous patients rehabilitated with ball and socket and locator retained mandibular 2-implant overdentures.
Materials and Methods: 14 edentulous patients were recruited to receive two mandibular implant overdentures and new conventional maxillary complete dentures. Mandibular implant overdentures (MIODs) were retained either by locator or ball attachment systems in random order. After 6 months of function, the attachment systems in the existing dentures were replaced with the other type of attachment. The prevalence of streptococci and staphylococci species (spp.) was analyzedusing blood-agar media at 3, 6 and 9 weeks after pick-up of attachments. The data was then collected, tabulated and statistically analyzed using SPSS.
Results: No significant difference was found in bacterial count of either Streptococcus or Staphylococcus spp. between two attachment systems (Ball and socket, Locator) at any of the evaluated time intervals with P-value > 0.05
Conclusions: Within the limitations of this study, it can be concluded that there is no difference in microbial flora between the two attachment systems. It can also be suggested that the locator attachments are valid treatment alternative for ball abutments to retain mandibular 2-implant overdentures from a biological point of view.

DOI

10.21608/edj.2019.72667

Authors

First Name

Reham

Last Name

Osman

MiddleName

B.

Affiliation

Lecturer, Faculty of Dentistry, Cairo University, Department of Prosthodontics

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Fahmy

MiddleName

-

Affiliation

Assistant Professor, Faculty of Dentistry, Cairo University, Department of Prosthodontics

Email

-

City

-

Orcid

-

Volume

65

Article Issue

Issue 3 - July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10701

Issue Date

2019-07-01

Receive Date

2020-02-21

Publish Date

2019-07-01

Page Start

2,651

Page End

2,659

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_72667.html

Detail API

https://edj.journals.ekb.eg/service?article_code=72667

Order

22

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

A Comparison of microbial flora in peri-implant sulcular fluid of ball versus locator retained mandibular implant overdentures. A randomized crossover study

Details

Type

Article

Created At

22 Jan 2023