Objective: to compare the accuracy of three different denture base materials used in maxillary edentulous arch
Materials and Methods: ten patients were selected, with completely edentulous arches, for each patient three finial PMMA denture bases were done using different construction technique pack and press, computer aided design/ computer aided manufacturing CAD/CAM milled and selective laser sintering (SLS) PMMA denture base All denture bases in this study were submitted for CBCT scanning for dimension accuracy and volume linear evaluation.
Results: The mean and standard deviation values were calculated for each group in each test. Data were explored for normality using Kolmogorov-Smirnov and Shapiro-Wilk tests, data showed parametric (normal) distribution. A statistically significant difference was found between (Heat cure acrylic denture), (CAD/CAM denture) and (Laser sintering denture)
Conclusion: also press and pack technique is more time consuming regarding number of visits but less dimensional changes than CAD/CAM and (SLS) selective laser sintering.

DOI

10.21608/edj.2019.72626

Keywords

denture base, dimension accuracy, CAD/CAM, SLS& dimension accuracy

Authors

First Name

Ahmed

Last Name

El-Sayed

MiddleName

Mohamed

Affiliation

Associate Professor of Removable Prosthodontics, Faculty of Dentistry, Cairo University.

Email

-

City

-

Orcid

-

First Name

Amr

Last Name

Salah El Din

MiddleName

-

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry, Fayoum University.

Email

-

City

-

Orcid

-

First Name

Inass

Last Name

AbuElmagd

MiddleName

Abdel Rahman

Affiliation

Associate Professor of of Oral Radiology, Faculty of Dentistry, Fayoum University.

Email

-

City

-

Orcid

-

Volume

65

Article Issue

Issue 3 - July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10701

Issue Date

2019-07-01

Receive Date

2020-02-21

Publish Date

2019-07-01

Page Start

2,635

Page End

2,640

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_72626.html

Detail API

https://edj.journals.ekb.eg/service?article_code=72626

Order

20

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Evaluating Dimension accuracy of three differently fabricated denture base materials

Details

Type

Article

Created At

22 Jan 2023