Abstract

Objective: to evaluate the internal fit of all ceramic restoration fabricated by two CAD/CAM milling systems using cone beam CT (CBCT).
Materials and methods: A total number of 20 all ceramic restorations were manufactured in this study, and were equally divided into two main groups (n=10) according to the type of CAD/CAM system used in the manufacturing process. Group I (Cerec in-lab system) and group II (Everest system) using the e.max CAD blocks specified for each milling system. specially designed stainless steel die was manufactured with specified dimensions. The die was scanned, the all ceramic restoration was designed and milled according to the different CAD/CAM milling systems used, and then crystallization procedure was carried. Duplication of the metal die into epoxy resin dies was performed and the final all ceramic restorations were the placed over the epoxy resin dies and examined for internal gap measurement using cone beam computed tomography (CBCT). Numerical data were explored for normality using Kolmogorov-Smirnov test of normality. Normally distributed (parametric data), were presented as mean, standard deviation and were compared between groups using independent t test. Non-parametric data were compared between groups using Mann Whiney U test. Gingival, axial and occlusal segments were compared using Friedman test and Wilcoxon signed rank test. The significance level was set at p < 0.05. Statistical analysis was performed with SPSS 18.0 for windows.
Results: Comparison between groups using the mean of the 3 successive sections in bucco-lingual section revealed that a higher mean value was recorded in Cerec for each of the gingival, axial and occlusal segments, with no statistically significant difference between groups (p=0.138, p=0.06, p=0.276 respectively), while in mesio distal section a higher mean value was recorded in Cerec in the gingival and axial segments, with no significant difference between groups (p=0.296, p=0.568 respectively). In the occlusal section, a higher mean value was recorded in Kavo Everest, with no statistically significant difference between groups (p=0.734). Comparison of gingival, axial and occlusal segments within the same group in bucco-lingual section revealed that in Kavo Everest group, a significantly higher mean value was recorded in occlusal segment in comparison to the gingival and axial segments (p=0.001). In cerec group, a significantly higher mean value was recorded in occlusal segment in comparison to the gingival and axial segments (p=0.00), while in mesio distal section , in Kavo Everest group, a significantly higher mean value was recorded in occlusal segment in comparison to the gingival and axial segments (p=0.00). In Cerec group, a significantly higher mean value was recorded in occlusal segment in comparison to the gingival and axial segments (p=0.00).
Conclusion: The technique of CAD/CAM milling system has affected the internal fit of CAD/CAM all-ceramic restorations.

DOI

10.21608/edj.2019.72614

Authors

First Name

Hesham A.

Last Name

Aboudorra

MiddleName

A.

Affiliation

DDS of Fixed Prosthodontic, Faculty of Dentistry, Alazhar University

Email

-

City

-

Orcid

-

First Name

Haitham

Last Name

Amr

MiddleName

-

Affiliation

Lecturer of Fixed Prosthodontic, Faculty of Dentistry, Fayoum University

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

El zohairy

MiddleName

-

Affiliation

Ass. Professor of Conservative Dentistry, Faculty of Dentistry, Cairo University

Email

-

City

-

Orcid

-

First Name

Amir

Last Name

Hafez

MiddleName

-

Affiliation

Lecturer of Conservative Dentistry, Faculty of Dentistry, Cairo University

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Hassan

MiddleName

A.

Affiliation

Ass. Lecturer of Oral Radiology, Faculty of Dentistry, Fayoum University

Email

-

City

-

Orcid

-

Volume

65

Article Issue

Issue 3 - July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10701

Issue Date

2019-07-01

Receive Date

2020-02-21

Publish Date

2019-07-01

Page Start

2,467

Page End

2,479

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_72614.html

Detail API

https://edj.journals.ekb.eg/service?article_code=72614

Order

2

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Internal fit evaluation of all ceramic restoration fabricated by two CAD/CAM milling systems using cone beam CT (CBCT)

Details

Type

Article

Created At

22 Jan 2023