72927

Effect of two different Overdenture attachments on the biting force and occlusal force distribution

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Objective: This study compared and evaluated the effect of two different implant retained Mandibular Overdenture attachments on the biting force and occlusal force distribution.
Materials and Methods: Fourteen completely edentulous male patients were selected and two implants were inserted for each patient. After 3 months of installation Patients were randomly divided into two equal groups: Group (I): Patients received conventional complete maxillary dentures opposed by Mandibular over dentures supported and retained by two conventional implants using ball attachment Group (II): Patients received conventional complete maxillary dentures opposed by Mandibular over dentures supported and retained by two conventional implants using locator attachment. Biting force was evaluated using I load star sensor. At time of prosthesis insertion, 3 months, 6 months, 9 months and 12 months. The T-Scan III digital occlusal system was used to record anterior and posterior percentage occlusal force (%OF) distribution.
Results: The result was revealed that there was no statistically significant difference in biting force and occlusal force distribution between the two different attachments (locator attachment and ball attachment) in retained Mandibular Overdenture.

DOI

10.21608/edj.2019.72927

Keywords

overdenture, biting force, occlusal force distribution

Authors

First Name

Mai

Last Name

Helmy

MiddleName

Adel

Affiliation

Lecturer, Removable Prosthodontics Department, faculty of dentistry, Cairo University

Email

-

City

-

Orcid

-

First Name

Marwa

Last Name

Kothayer

MiddleName

-

Affiliation

Lecturer, Removable Prosthodontics Department, faculty of dentistry, Ain Shams University

Email

-

City

-

Orcid

-

Volume

65

Article Issue

Issue 2 - April (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10694

Issue Date

2019-04-01

Receive Date

2020-02-22

Publish Date

2019-04-01

Page Start

1,723

Page End

1,732

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_72927.html

Detail API

https://edj.journals.ekb.eg/service?article_code=72927

Order

34

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect of two different Overdenture attachments on the biting force and occlusal force distribution

Details

Type

Article

Created At

22 Jan 2023