Beta
72831

Influence of two different implant designs on implant stability

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Aim of the study: To evaluate and compare the influence of the conventional solid-structure (CSS) implants versus the direct metal laser sintering (DMLS) implants regarding primary and secondary stability.
Materials and methods: A total of 12 implants of two different designs were tested , six partially edentulous male patients having full set of teeth upper arch opposed by Kennedy class I lower arch with second premolar as last standing abutment bilaterally received twelve implants at the second molar area bilaterally, each patient received two implants of the same size, diameter and implant abutment connection, one conventional solid-structure (CSS) implants (control group) at the right side and one direct metal laser sintering (DMLS) implant (test group) at the left side. Primary and secondary implant stability were measured and compared by resonance frequency analysis using osstell device at time of implant insertion, weeks 1, 4, and 12 after implant insertion.
Result: there was a statistically insignificant difference in stability values between direct metal laser sintering (DMLS) implants (test group) and conventional solid-structure (CSS) implants (control group) throughout the follow up periods except at 12 weeks follow up period there was a statistically significant increase in stability values in direct metal laser sintering (DMLS) implant (test group) compared to the conventional solid-structure (CSS) implants (control group).
Conclusion: Direct metal laser sintering (DMLS) implants showed higher secondary stability values than conventional solid-structure (CSS) implants.

DOI

10.21608/edj.2019.72831

Keywords

Implant design, implant stability, osstell device, direct metal laser sintering implants

Authors

First Name

Maha

Last Name

Nagi

MiddleName

-

Affiliation

Lecturer, Removable Prosthodontics Department, Faculty of Dentistry, British University in Egypt

Email

-

City

-

Orcid

-

Volume

65

Article Issue

Issue 1 - January (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10686

Issue Date

2019-01-01

Receive Date

2020-02-22

Publish Date

2019-01-01

Page Start

691

Page End

699

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_72831.html

Detail API

https://edj.journals.ekb.eg/service?article_code=72831

Order

32

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Influence of two different implant designs on implant stability

Details

Type

Article

Created At

22 Jan 2023