Abstract

An experimental study was conducted to determine the performance of two evaporative cooling systems, as well as the gradients of temperature and humidity along a greenhouse. The first system was the cooling unit, (CU) compared with the traditional fan-pad one, (F-P). The cooling unit was connected with two perforated ducts inside the greenhouse. The air temperatures and relative humidities on the longitudinal axis were measured outside and just after leaving the media and at each one meter from the pad media. They were also, measured in the traverse axis parallel to the pad media at distances 0.5, 1.5, 2.5 and 3.5 m from the edge of the greenhouse. A steady state mathematical model was modified to predict the greenhouse air temperature according to the state of the air just leaving the cooling media. According to the experimental results, the non-uniform temperature changes were observed along the greenhouses for the two systems. The average temperatures of the CU greenhouse were 27.9, 30.4, 33.2, 29.1 and 27.9 oC for outside ambient temperatures of 28.7, 32.4, 35.4, 32.1 and 29.4 oC, respectively. The ranges of temperature gradient inside the CU greenhouse were 2.1, 2.1, 2.2, 2.2, and 2.1 oC. While in the F-P greenhouse, they were 5.9, 7.4, 8.2, 5.9 and 6.1 oC for the same ambient temperatures. The average air temperature entering to greenhouse was approximately 6.82 and 7.09 ºC lower than the outside air temperature for CU and F-P systems. The greenhouse of CU system was higher in the relative humidity than F-P one. The average relative humidities were 69.0 and 61.8% for the CU and F-P greenhouses, respectively, with increase percent 12.38%. The averages CU efficiencies were 77.55% and 74.79% in the first and second days, respectively, while they were 72.97% and 70.19% for the same days for F-P system. Consequently, the CU system was averagely more efficient than the F-P system by 6.29% and 6.58%. The water flow rate of the two systems to permit optimum wetness and air saturation were 5.6 and 6.5 L/min for the CU and F-P evaporative cooling systems, respectively. The saving percentage in water circulation was 16.1% for the CU system. The total yield per plant was 6.24 and 5.48 kg/plant for the CU and F-P systems, respectively. The CU system increased the yield per plant with 13.82% over the F-P system.

DOI

10.21608/asejaiqjsae.2015.2742

Keywords

Greenhouses, Evaporative cooling, Fan- Pad system- cooling efficiency

Authors

First Name

Youssef,

Last Name

G.D.M.

MiddleName

-

Affiliation

Protected Cultivation Research Deprt., Horticultural Research Institute, A.R.C., Giza, Egypt

Email

-

City

-

Orcid

-

First Name

Yakout,

Last Name

T.R.

MiddleName

-

Affiliation

Protected Cultivation Research Deprt., Horticultural Research Institute, A.R.C., Giza, Egypt

Email

-

City

-

Orcid

-

First Name

Doaa, M.

Last Name

Mostafa

MiddleName

-

Affiliation

Vegetable Research Deprt., Horticultural Research Institute A.R.C., Giza, Egypt

Email

-

City

-

Orcid

-

Volume

36

Article Issue

January-March

Related Issue

356

Issue Date

2015-01-01

Receive Date

2015-03-01

Publish Date

2015-03-30

Page Start

80

Page End

94

Print ISSN

1110-0176

Online ISSN

2536-9784

Link

https://asejaiqjsae.journals.ekb.eg/article_2742.html

Detail API

https://asejaiqjsae.journals.ekb.eg/service?article_code=2742

Order

10

Type

Original Article

Type Code

53

Publication Type

Journal

Publication Title

Alexandria Science Exchange Journal

Publication Link

https://asejaiqjsae.journals.ekb.eg/

MainTitle

Improving Performance of the Evaporative Cooling System inside the Greenhouses and Its Effect on Tomato Productivity

Details

Type

Article

Created At

22 Jan 2023