Beta
390038

Validity and Reliability of Modified Sphygmomanometer Versus Jamar Dynamometer in Measuring Hand Grip Strength for Patients with Distal Radius Fractures

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Abstract Background: The modified sphygmomanometer and Jamar grip dynamometer are important tools to measure the hand grip strength (HGS). Aim of Study: Is to test the concurrent validity, interrater and test-retest reliability of bag modified sphygmomanometer and Jamar grip dynamometer. Subjects and Methods: Seventy patients of distal radi-us fracture (67 colles' and 3 smith fracture) with mean age 45.03±10.45 years, were recruited to evaluate the grip strength by Jamar grip dynamometer and bag modified sphygmoma-nometer after being updated with the aneroid sphygmomanom-eter (KBM). Validity was explained by the correlation between the strength of hand grip that was assessed by modified sphyg-momanometer and Jamar dynamometer by Person Correlation Coefficient. Test-retest reliability and inter-rater reliability were expressed as Intra-class Correlation Coefficients (ICCs). All data was analyzed by (SPSS) version 25 for windows. Results: There was a correlation between strength of hand grip that was assessed by modified sphygmomanometer and Ja-mar dynamometer; was strong correlation with positive signif-icant in concurrent validity (r=0.852, p=0.001), The modified sphygmomanometer showed excellent in test-retest reliability with Intraclass correlation coefficient (ICC) was 0.996 and in interrater reliability with 0.993 Intraclass correlation coeffi-cient. Conclusion: The bag modified sphygmomanometer is a concurrently valid, test-retest and interrater reliable device to measure hand grip of distal radius fracture patients with differ-ent gender and fixation types.

DOI

10.21608/mjcu.2024.390038

Keywords

Distal radius fracture, Grip dynamometer, Bag modified sphygmomanometer, Pneumatic grip in-struments, Hydraulic grip instruments

Authors

First Name

EMAN H. ANWAR, M.Sc.*; SALWA F. ABD EL MAJEED, Ph.D.*; MOHAMED E. SHALABY, Ph.D.* and

Last Name

EMAD A. ABDEL ATI, M.D.**

MiddleName

-

Affiliation

The Department of Physical Therapy for Musculoskeletal Disorder and its Surgery*, Faculty of Physical Therapy, Cairo University and Orthopedics Department**, Faculty of Medicine, Cairo University

Email

-

City

-

Orcid

-

Volume

92

Article Issue

09

Related Issue

51209

Issue Date

2024-09-01

Receive Date

2024-11-02

Publish Date

2024-09-01

Page Start

849

Page End

856

Print ISSN

0045-3803

Online ISSN

2536-9806

Link

https://mjcu.journals.ekb.eg/article_390038.html

Detail API

https://mjcu.journals.ekb.eg/service?article_code=390038

Order

390,038

Type

Original Article

Type Code

263

Publication Type

Journal

Publication Title

The Medical Journal of Cairo University

Publication Link

https://mjcu.journals.ekb.eg/

MainTitle

Validity and Reliability of Modified Sphygmomanometer Versus Jamar Dynamometer in Measuring Hand Grip Strength for Patients with Distal Radius Fractures

Details

Type

Article

Created At

30 Dec 2024