3D Evaluation of Marginal Fit of Interim Crowns Fabricated using Conventional, Virtual and Three-Dimensional Printed Working Dies. (In Vitro Study).

Article

Last updated: 28 Dec 2024

Subjects

-

Tags

Pharmaceutical, Dental, and medical disciplines whether they are descriptive, analytical, experimental, or basic studies

Abstract

Background: The working die system used in dental prosthesis fabrication impacts the accuracy of dental prosthesis. Conventional, virtual, and 3D printed dies are used in various clinical scenarios. The accuracy of 3D printed models for diagnosis has been extensively studied. There is a lack of research on the marginal fit of interim single crowns made with 3D printed dies compared to conventional and virtual dies. Aim of the study: to evaluate the marginal fit of interim crowns fabricated using conventional, virtual, and three-dimensional printed working Dies. Materials and methods: A total of 18 interim crowns were milled and divided into three groups according to the die system on which they were fabricated; group A (fabricated on conventional dies), group B (fabricated on virtual dies) and group C (fabricated on 3D printed dies). Six physical impressions using polyvinyl siloxane material were taken to create conventional dies (group A) for maxillary right first molar. Additionally, six optical scans were performed to fabricate virtual dies (group B) and printed dies (group C). Interim crowns were milled, and a triple scan protocol was used to evaluate their marginal fit. Results: The virtual group demonstrated significantly better marginal fit compared to the other groups (p < 0.001). However, there was no statistically significant difference between the 3D printed and conventional groups. Conclusion: virtual dies yielded the highest marginal fit, while the conventional and 3D printed dies produced comparable results. The marginal fit of all interim crowns fell within the clinically acceptable range of 30 to 141 µm.

DOI

10.21608/jfcr.2023.221188.1051

Keywords

digital techniques, Marginal fit, milling method, three-dimensional printing method, and working dies

Authors

First Name

bassem

Last Name

ahmed

MiddleName

Maged

Affiliation

BDS. Postgraduate student, Fixed Prosthodontics Department - Faculty of Oral and Dental Medicine- Misr International University-Cairo- Egypt

Email

bassem112714@miuegypt.edu.eg

City

-

Orcid

-

Volume

3

Article Issue

2

Related Issue

44626

Issue Date

2023-12-01

Receive Date

2023-07-05

Publish Date

2023-12-01

Page Start

170

Page End

189

Online ISSN

2786-023X

Link

https://jfcr.journals.ekb.eg/article_328508.html

Detail API

https://jfcr.journals.ekb.eg/service?article_code=328508

Order

8

Type

Original research articles

Type Code

1,936

Publication Type

Journal

Publication Title

Journal of Fundamental and Clinical Research

Publication Link

https://jfcr.journals.ekb.eg/

MainTitle

3D Evaluation of Marginal Fit of Interim Crowns Fabricated using Conventional, Virtual and Three-Dimensional Printed Working Dies. (In Vitro Study).

Details

Type

Article

Created At

28 Dec 2024