Beta
363806

Evaluation of retention values of different telescopic crown attachment materials in implant retained overdenture (an in vitro study)

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Removable Prosthodontics

Abstract

The aim of this study was examining the impact of various telescopic crown attachment materials on implant-retained mandibular overdentures' retention.
Material and Methods: completely edentulous mandibular epoxy models were constructed; wherein various material combinations have been used for constructing telescopic attachments for two implants placed in the canine area. The traditional standardized method was used to fabricate thirty-three identical mandibular overdentures. Based on the material utilized in constructing the secondary coping, the study groups were divided into three categories: PEEK/PEEK, PEEK/ZrO2, and PEEK/CoCr. For each research group, primary PEEK copings were created. On a prefabricated abutment, primary copings were cemented in place. In the intended insertion path, secondary copings were positioned over the primary copings and then lifted up into the overdentures' intaglio surface. In order to assess each group's retention value, a vertical load of 100 N was adjusted in the universal testing machine. Insertion-removal cycles were applied repeatedly using a cyclic loading machine to simulate nearly 10 years of clinical use.
Results: The mean retention values for PEEK-PEEK, PEEK-ZrO2, and PEEK-CoCr groups varied from 2.19 to 1.16 N, 5.78 to 2.51 N, and 1.15 to 0.31 N, respectively. The retention varied statistically significantly throughout the study groups. PEEK/PEEK recorded the highest retention value, followed by PEEK/ZrO2 and PEEK/CoCr, respectively.
Conclusions: The telescopic crown materials have an impact on the retention forces, even in cases when the identical crown design is selected. Within the limitations of this investigation, the combination of PEEK-PEEK, followed by PEEK-ZrO2, demonstrated superior retention results.

DOI

10.21608/edj.2024.288610.3035

Keywords

telescopic attachment, retention, Zirconia, PEEK, Cobalt-chromium

Authors

First Name

Sherif

Last Name

Abdel Hamid

MiddleName

Mohamed

Affiliation

Lecturer of prosthodontics, Prosthodontics Department, Faculty of Dentistry, Pharos University, Egypt

Email

sherif.abdelhamid@pua.edu.eg

City

Alexandria

Orcid

0000-0002-5985-417X

First Name

Rim

Last Name

Selima

MiddleName

Adel

Affiliation

Teaching Assistant, Prosthodontics Department, Faculty of Dentistry Pharos University, Egypt. Egypt.

Email

reem.adel20087@gmail.com

City

Alexandria

Orcid

0009-0004-5384-4941

First Name

Mohamed

Last Name

Basiony

MiddleName

Zaki

Affiliation

Lecturer of prosthodontics, Prosthodontics Department, Faculty of Dentistry, Pharos University, Egypt

Email

mohamed.zaki@pua.edu.eg

City

Alexandria

Orcid

0000-0002-0357-7062

Volume

70

Article Issue

3

Related Issue

48886

Issue Date

2024-07-01

Receive Date

2024-05-15

Publish Date

2024-07-01

Page Start

2,637

Page End

2,644

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_363806.html

Detail API

https://edj.journals.ekb.eg/service?article_code=363806

Order

363,806

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Evaluation of retention values of different telescopic crown attachment materials in implant retained overdenture (an in vitro study)

Details

Type

Article

Created At

23 Dec 2024