Beta
387725

Efficacy of transalveolar pressure measurement as a monitoring parameter for lung recruitment in postcardiac surgery hypoxic patients

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

-

Abstract

: Lung atelectasis is a common complication post-cardiac surgery that can affect patient’s outcomes significantly. The current study aimed to evaluate the efficacy of transalveolar pressure measurement (PTA) using esophageal manometer as a monitoring parameter during a modified stepwise staircase lung recruitment employing adaptive ventilation mode (AVM) in postcardiac surgery hypoxic patients.: This study was a prospective case series study.Methods: The study was carried out on 62 adult patients who were undergone on-pump cardiac surgeries. After haemodynamic stabilization of the patient in ICU, esophageal manometer catheter had been inserted then a modified stepwise staircase alveolar recruitment maneuver was done with the use of the transalveolar pressure as the main parameter for the monitoring of the effectiveness and safety of the recruitment maneuver. Agreement between parameters was done and weighted kappa, standard error and confidence intervals at 95% (95% CI) were calculated.: During the alveolar recruitment maneuver, the PTA Insp detected 96.7% of the patients with alveolar overdistention and the PTA Exp detected 98.3% of the patients with alveolar optimum PEEP. Statistical significant improvement in both hypoxic index and ultrasound lung aeration score from before to after alveolar recruitment.: Transalveolar pressure inspiratory and expiratory were accurate monitoring parameters for alveolar overdistention and optimum PEEP detection selectively.
: ALI: Acute lung injury; ARDS: Adult respiratory distress syndrome; AVM: Adaptive ventilation mode; Cdyn: Compliance Dynamic; ETT: Endotracheal tube; IBW: Ideal body weight; ICU: Intensive care unit; MBP: Mean blood pressure; MVTarget:Minute volume target; PEEP: Positive end expiratory pressure; PES: Esophageal pressure; PLimit: Pressure limit; PPL: Pleural pressure; PTA: Transalveolar pressure measurement; PTA Exp: Expiratory transalveolar pressure; PTA Insp: Inspiratory transalveolar pressure; RM: Recruitment maneuvers; SpO2: Percutaneous Oxygen saturation

DOI

TEJA-2021-0016

Keywords

atelectasis, alveolar recruitment, AVM, esophageal manometer, lung ultrasound

Authors

First Name

Ibrahim Mabrouk

Last Name

Ibrahim

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Yousef

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Amal

Last Name

Sabry

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ayman

Last Name

Khalifa

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

37

Article Issue

1

Related Issue

51159

Issue Date

2021-01-01

Receive Date

2021-02-01

Publish Date

2021-01-01

Page Start

145

Page End

151

Print ISSN

1110-1849

Online ISSN

1687-1804

Link

https://egja.journals.ekb.eg/article_387725.html

Detail API

https://egja.journals.ekb.eg/service?article_code=387725

Order

387,725

Publication Type

Journal

Publication Title

Egyptian Journal of Anaesthesia

Publication Link

https://egja.journals.ekb.eg/

MainTitle

Efficacy of transalveolar pressure measurement as a monitoring parameter for lung recruitment in postcardiac surgery hypoxic patients

Details

Type

Article

Created At

21 Dec 2024