Beta
118241

REDUCE ENERGY AND HEAT STRESS IN CLOSED RABBIT HOUSING UNDER EGYPTIAN DELTA ZONE CONDITIONS

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Agricultural Constructions Engineering

Abstract

Many rabbit housing in Egypt were constructed without systematic design models from the viewpoint of sizing evaporative pad cooling system were determined by subtle mathematical models to solve this problem. Four commercial rabbit houses located at 30.95°N and 31.09°E and the pad fan evaporative cooling system were used to reduce the energy and side effects of heat stress on rabbit housing during summer 2017. Three different mathematical forms these forms were ASHRAE form (form 1); airflow depended upon the volume of the house (form 2), and heat balance (from 3). The house that operated with pad fan evaporative cooling and full pad area facing the fan had the best conditions for rabbits and the highest values of cooling performance. Therefore, the actual results for the previous house were the lowest indoor temperature was 26.85°C, the highest indoor relative humidity was 67.83 %, the highest saturation efficiency of cooling was 76.28%, the highest cooling potential was 7.25 °C and the highest value of the temperature-humidity index was 25.6 °C. Finally, when compared the obtained results from these houses with the results from calculation models, can found that these houses related nearly with the heat balance model.

DOI

10.21608/mjae.2020.42004.1006

Keywords

Rabbit, heat balance, heat stress, Evaporative cooling

Authors

First Name

Said E.

Last Name

AbouZaher

MiddleName

-

Affiliation

Assist. Prof., Agricultural Engineering Dept., Fac. of Agriculture, Kafr El-Sheikh University, Egypt.

Email

said.abouzaher@agr.kfs.edu.eg

City

-

Orcid

-

First Name

Mohammed R.

Last Name

Darwesh

MiddleName

-

Affiliation

Assoc. Prof., Agricultural Engineering Dept., Fac. of Agriculture, Tanta University, Egypt.

Email

rmdarwish@yahoo.com

City

-

Orcid

-

First Name

Mohamed S.

Last Name

Ghoname

MiddleName

-

Affiliation

Assist. Prof., Agricultural Engineering Dept., Fac. of Agriculture, Tanta University, Egypt.

Email

mohamed.ghonaim@agr.tanta.edu.eg

City

Tanta

Orcid

0000-0002-0465-1156

Volume

37

Article Issue

4

Related Issue

18182

Issue Date

2020-10-01

Receive Date

2020-09-07

Publish Date

2020-10-01

Page Start

373

Page End

392

Print ISSN

1687-384X

Online ISSN

2636-3062

Link

https://mjae.journals.ekb.eg/article_118241.html

Detail API

https://mjae.journals.ekb.eg/service?article_code=118241

Order

5

Type

Original Article

Type Code

1,326

Publication Type

Journal

Publication Title

Misr Journal of Agricultural Engineering

Publication Link

https://mjae.journals.ekb.eg/

MainTitle

REDUCE ENERGY AND HEAT STRESS IN CLOSED RABBIT HOUSING UNDER EGYPTIAN DELTA ZONE CONDITIONS

Details

Type

Article

Created At

23 Jan 2023