Beta
158602

Intra-ocular Lens Master V4 versus LenStar LS900 in Intra-ocular Lens Power Calculation and Postoperative Refraction Prediction

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

Clinical Research (Surgical)

Abstract

Background: The non-contact optical methods are preferable in Intra-ocular Lens (IOL) power calculation as they have higher resolution, better patient tolerance and greater acceptability. Aim: to compare between LENSTAR LS900 and IOL Master V4 in IOL power calculation. Material and Methods: This prospective comparative study included 60 eyes of 40 cataract patients. Patients with immature cataract of any age and both genders were included while those with dense cataract, media opacities, previous ocular diseases or surgeries or intraoperative complications were excluded. Patients were assessed by a complete comprehensive ophthalmic evaluation. Each patient was evaluated twice, one by the IOL Master and the other by the LENSTAR LS900. Outcome measures were axial length (AL), vertical keratometric dioptric power (K1), horizontal keratometric dioptric power (K2), and IOL power measurements. Results: The mean age of the patients was 67.08 ± 5.34 years. Thirty-five patients were males and 25 were females. The IOL master and LENSTAR were similar (p>0.05) in terms of the AL (24.82 ± 2.21and 24.80 ± 2.20), K1 (43.13 ± 1.66 and 43.14 ± 1.68), K2 (44.14 ± 1.56 and 44.27 ± 1.52) and IOL power (16.86 ± 5.24 and 16.84 ± 5.26). The target refraction on IOL master was -0.01 ± 0.06 compared with 0.04 ± 0.10 on LenStar. The actual refraction was 0.00 ± 0.33. There were non-significant differences between target and actual refractions on both devices (p>0.05). Conclusion: Both the optical biometers, IOL Master and LENSTAR provide similarly precise biometry and IOL power calculation in cataract patients.  

DOI

10.21608/scumj.2021.158602

Keywords

Optical biometry, IOL power calculation, Target refraction

Authors

First Name

Sara

Last Name

Sallam

MiddleName

A

Affiliation

Ophthalmology Department, Faculty of Medicine, Suez Canal University Hospitals, Egypt

Email

sara.abdelhay@med.suez.edu.eg

City

-

Orcid

-

First Name

Moataz

Last Name

Sallam

MiddleName

A

Affiliation

Ophthalmology Department, Faculty of Medicine, Suez Canal University Hospitals, Egypt

Email

moataz.sallam@med.suez.edu.eg

City

-

Orcid

0000-0003-4759-4849

First Name

Mohamed

Last Name

Shahin

MiddleName

E

Affiliation

Ophthalmology Department, Faculty of Medicine, Suez Canal University Hospitals, Egypt

Email

meeishahin@gmail.com

City

-

Orcid

-

First Name

Tarek

Last Name

Radwan

MiddleName

M

Affiliation

Ophthalmology Department, Faculty of Medicine, Suez Canal University Hospitals, Egypt

Email

radwan_tarek@hotmail.com

City

-

Orcid

-

Volume

24

Article Issue

1

Related Issue

22901

Issue Date

2021-03-01

Receive Date

2021-03-23

Publish Date

2021-03-01

Page Start

12

Page End

19

Print ISSN

1110-6999

Online ISSN

2090-2581

Link

https://scumj.journals.ekb.eg/article_158602.html

Detail API

https://scumj.journals.ekb.eg/service?article_code=158602

Order

2

Type

Original Article

Type Code

938

Publication Type

Journal

Publication Title

Suez Canal University Medical Journal

Publication Link

https://scumj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023